MLDV Direct Vent Gas Fireplace Model: MLDV500 Installation & Operating Instructions WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. – – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
CONTENTS MLDV Series Gas Fireplace Thank you and congratulations on your purchase of a Vermont Castings Group Fireplace. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Important Safety Information...................................... 3 Checking Gas Pressure - SCS ...................
IMPORTANT SAFETY INFORMATION MLDV Series Gas Fireplace OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. WARNING INSTALLER • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous.
IMPORTANT SAFETY INFORMATION MLDV Series Gas Fireplace IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. IMPORTANT: PLEASE READ THE FOLLOWING CAREFULLY It is not unusual for gas fireplaces to give off some odor the first time it is burned. This is due to the manufacturing process.
product features MLDV Series Gas Fireplace product SPECIFICATIONS • This appliance has been certified for use with • • • • • • Insulation Board either natural or propane gas. See appropriate data plates. This appliance is not for use with solid fuels. The appliance is approved for bedroom or bedsitting room installations. The appliance must be installed in accordance with local codes if any. If none exist use the current installation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.
FIREPLACE and FRAMING DIMENSIONS MLDV Series Gas Fireplace 2256M” (565 mm) 2256M” (565 mm) (9 36 21 56M m ” m ) m m ) 1/2” or 5/8” 91 Min. Rough Opening Width (4256O” 91080 mm) 17 56O ”( 72 5256M” (1327 mm) 5256M” (1327 mm) 30(6 ” (784 mm) 20 6 ” (524 mm) Min. Rough Opening Depth Min.
installation information MLDV Series Gas Fireplace Before You Start Fireplace Location Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received.
clearances MLDV Series Gas Fireplace WARNING Clearances to combustibles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
SECURe FIREPLACE to floor or framing NOTE The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.
VENTING INSTALLATION MLDV Series Gas Fireplace NOTICE WARNING Venting installation Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life. installation precautions Consult local building codes before beginning the installation.
Venting installation MLDV Series Gas Fireplace The appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent configuration, the appliance can be converted by following the steps below. When removing and refitting the plates and adapter, be sure the associated gaskets are undamaged and refitted as required.
Venting installation Horizontal sections of this vent system require a minimum of 3” clearances to combustibles at the top of the flue and 1” clearance at the sides and bottom until the flue penetrates the outside wall. A minimum 1” clearance all around the flue is acceptable at this point of penetration. If vertical rise is 7Z\x” feet or higher when top venting, the clearance to combustibles is 1” on all sides of the horizontal run.
WARNING Venting installation Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
venting installation MLDV Series Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL G V H A D L V E C B V F Figure 11 Horizontal Vent Termination Locations B Fixed Closed Ope rable V B B V Operable B B J X X AIR SUPPLY INLET V K X AREA WHERE TERMINAL IS NOT PERMITTED Canadian Installations1 CFM145a DV Termin Location 5/01/01 Rev.
venting installation MLDV Series Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Alcove Applications* Inside Corner Outside Corner G= Combustible 6" (152 mm) G V Noncombustible 2" (51 mm) V F= Combustible 6" (152 mm) Noncombustible 2" (51 mm) F Balcony with perpendicular side wall Balcony with no side wall D C C V E O E = Min. 2” (51 mm) for non-vinyl sidewalls Min. 12” (305 mm) for vinyl sidewalls O = 8’ (2.
MLDV Series Gas Fireplace REAR WALL VENT INSTALLATION (5" x 8" VENTING ONLY) When installed as a rear vent unit, this appliance may be vented directly to a termination located on the rear wall behind the appliance. Only an Vermont Castings Group brand termination is allowed for this application. • The maximum horizontal distance between the rear of the appliance and the termination is 20" (508 mm). Figure 14 Maximum 20" venting installation 2.
venting installation MLDV Series Gas Fireplace Inerior Wall Surface Vent Cap (Horizontal Termination) Vent Cap Firestop T HO Apply Mastic to all Four Sides FP1957 Wood Screw Screw Figure 17 Install Horizontal Termination T HO FP1956 Nut Bolt Wood Screw Figure 18 Install Duravent/Selkirk Vinyl Siding Standoff and Termination notice 6. Slide the stop over the vent pipe before connecting the FP1956 horizontal run to the vent cap. Figure 19 vinyl siding 7.
venting installation MLDV Series Gas Fireplace The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace (or the top of the Transition Elbow) to the face of the finished outside wall or the mounting flange of the termination. • The maximum number of 90° elbows per side wall installation is three (3).
venting installation MLDV Series Gas Fireplace • For each 45° elbow installed in the horizontal run, the length of the horizontal run MUST be reduced by 18" (457 mm). This does not apply if the 45° elbows are installed on the vertical part of the vent system. The maximum number of elbow degrees in a system is 270°.
venting installation MLDV Series Gas Fireplace 91/2" (241 mm) Screws Firestop Minimum 4" Clearance Ground 91/2" (241 mm) Window Well 12" Minimum Combustible Wall Gravel Drain 71/2" (190 mm) Noncombustible Wall Foundation Wall FP1954 Figure 26 FP1954 Dimensions Exterior Wall Framing for 4" x 65/8" orwall 4" framing x 7" Below Grade Installations When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended.
venting installation MLDV Series Gas Fireplace VERTICAL THROUGH-THE-ROOF APPLICATIONS Install restrictor disc as shown in Figure 29 for vertically vented applications. Up to two (2) restrictor discs may be needed for 40' installation. This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows.
venting installation MLDV Series Gas Fireplace • Two sets of 45°elbows offsets may be used within the INSTALLATION FOR VERTICAL TERMINATION • 1. Determine the route your vertical venting will take. If ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 32 to avoid cutting load bearing members.
venting installation MLDV Series Gas Fireplace Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three (3) nails per side. Figure 34. 2. Assemble the desired lengths of pipe and elbows necessary to reach from the burner system flue up through the firestop. Be sure pipe and elbow connections are fully twist-locked. Page 18, Figure 15.
Flex vent installation MLDV Series Gas Fireplace 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent components can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Flex kits may not be modified. Flex kits may be added to the end of a vent run made of rigid vent sections using pipe manufacturer's approved flex to pipe adapters.
flex vent installation MLDV Series Gas Fireplace D. Attaching flexible venting to vertical termination assemblies. 1. When using Duravent pipe, an Vermont Castings Group flex-to-pipe adapter and/or rigid pipe section(s) is required to connect the flexible vent assembly to the vertical termination by using three self-penetrating screws. 2. Review Figure 39 and corresponding instructions for proper overlap, clamp and screw placement. 3.
FLEX vent installation MLDV Series Gas Fireplace 4" x 7" Flex Pipe If you prefer to use 4" x 7" flex pipe, you must install model 7TDVP58 reducer (5" x 8" to 4" x 7") onto the fireplace collar. Then follow the assembly guidelines for 5" x 8" flex venting.
fireplace installation MLDV Series Gas Fireplace check gas type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. External Regulator 100 gallon (min) Propane/LP Supply Tank WARNING Installing gas piping to fireplace / burner system location A qualified installer or service person must connect appliance to gas supply.
fireplace installation Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. CAUTION WARNING MLDV Series Gas Fireplace A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8” NPT pressure tapping point should be installed upstream of the appliance. Figure 46 Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe.
CHECK GAS PRESSURE and Electrical installation - MILLIVOLT MLDV Series Gas Fireplace This fireplace will work without any electrical supply. Electricity is only needed to operate blower. WARNING NOTE: If installed in mobile home, fireplace must be bolted securely to floor. Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service.
REMOTE WALL SWITCH INSTALLATION MLDV Series Gas Fireplace A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 48. Do not extend beyond the wall switch wire length provided. NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.
OPTIONAL FAN/BLOWER SYSTEM MLDV Series Gas Fireplace 5. Remove hearth brick and wall brick panels. 6. Disconnect the gas line to the valve. 7. Remove screws securing engine base to firebox floor and lift engine up to remove. 8. Two (2) magnetic strips have been supplied to secure each blower to the firebox floor. Place on bottom of each blower before installing. Figure 50 9. The blowers are to be inserted flat through the engine cutout in the firebox floor. Slide each blower over to the sidewall location.
OPTIONAL FAN/BLOWER SYSTEM MLDV Series Gas Fireplace Variable Fan Control 110/115V AC Blower Plug 1 2 Thermal Sensor ON White (Hi Temp) OFF White (Hi Temp) Black White Green Blower Motor Blower Black Motor White WARNING Figure 55 Blower Wiring Diagram Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly FP1910 grounded three prong receptacle.
OPERATING INSTRUCTIONS - MILLIVOLT MLDV Series Gas Fireplace WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly. B. BEFORE OPERATING smell all around the appliance area for gas.
OPERATING INSTRUCTIONS - MILLIVOLT MLDV Series Gas Fireplace approved leak testing method You may check for gas leaks with the following methods only: • Soap and water solution WARNING Lighting pilot for the first timE If using a soap and water solution to test for leaks, DO NOT spray solution onto control body. • An approved leak testing spray DANGER • Electronic sniffer NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
OPERATING INSTRUCTIONS - MILLIVOLT MLDV Series Gas Fireplace Lighting burner OFF RS The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. ON main burner switch On/Off/RS Switch Lighting the burner Depress and turn the knob counterclockwise to the “ON” position.
CHECK GAS PRESSURE and Electrical installation - Signature Command MLDV Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve. 3.
ELECTRICAL INSTALLATION MLDV Series Gas Fireplace JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with minimum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall. Junction box was installed at the factory. 3. The junction box cover has a factory installed “romex” style strain relief connector.
ELECTRICAL INSTALLATION MLDV Series Gas Fireplace Optional AC Module To Junction Box in Fireplace Pilot { Plug in Connector Optional Blower Optional Light { White Black White Black Optional { White Black Aux. Green Connector Pin To Control Board Input 300 Watt Max.
OPTIONAL FAN BLOWER SYSTEMS The black and white wires on the AC box wiring harness are marked ‘Blower’, ‘Light’ and ‘Aux’. It is important to use the wires marked ‘Blower’ or the control will not work correctly. WARNING WARNING Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
OPTIONAL FAN BLOWER SYSTEMS MLDV Series Gas Fireplace BLOTSDV AUTOMATIC THERMOSTAT BLOWER 120VAC Receptacle Junction Box BLACK GREEN WHITE BLACK WHITE BLACK BLACK Speed Control Figure 60 BLOTSDV Blower Wiring Diagram Before installing the blower, wire the receptacle into an electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance FP2685 with prevailing codes.
OPERATING INSTRUCTIONS - SIGNATURE COMMAND MLDV Series Gas Fireplace WARNING for your safety read before lighting If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions. B. BEFORE OPERATING smell all around the appliance area for gas.
MLDV Series Gas Fireplace OPERATING INSTRUCTIONS - SIGNATURE COMMAND OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3. With five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 38. If you do not smell gas, go to next step. 4.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS MLDV Series Gas Fireplace FEATURES To Thermopile RF Receiver ON/OFF Command Center To Sensor • Easy Access Function Operation and System Configuration • Operation Confirmation/Fault Diagnostic Indications (LED/Buzzer) • ON/OFF/HI/Med/Low Operation • Optional Wall Mounting Control Board • Electronic Ignition • Pilot Lockout safety feature • Electric Power Regeneration from Thermopile to save • • • • • • • battery 6-hour Automatic Shut Down Option Conve
MLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center. COLD CLIMATE OPTION Choose the Mode That Best Suits Your Needs The Signature Command System is designed to operate in either Standing Pilot or Intermittent Pilot mode.
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below). For memory feature. Pilot Safety Lockout Function 1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens.
MLDV Series Gas Fireplace glass removal and brick installation Glass Frame Removal CAUTION 1. Remove access panel by lifting up and out. 2. Release three (3) clamps on bottom of fireplace. Figure 62 3. Tilt glass frame out and lift glass frame up until it clears hook on top of fireplace. 4. Set glass frame aside. Glass Frame Each clamp has a quick spring force. When reinstalling clamps, keep fingers clear. ! WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED.
logs and rock wool installation MLDV Series Gas Fireplace 1. Distribute one layer of rock wool to cover all round burner ports. Do not cover rectangular slots, located in front and rear. Figure 64 FP1983 Figure 64 Rock Wool Placement on Burner. FP1983 MLDV rock wool place 2. Place log #1 by setting the log over the rear bracket over the two pins. Figure 65 Log #1 LG543 Figure 65 Install log #1 75D0004 WARNING LG543 Note: Placing rock wool on burner provides glowing MLDV log #1 embers.
log installation MLDV Series Gas Fireplace 3. Place log #2 at angle across the burner by setting the logs over the two pins located on top of the burner. Figure 66 Log #2 Figure 66 Install Log #2 LG544 4. Place log #3 at an angle over log #2 toward the back by matching the rectangular notch on the bottom of this log with the rectangular protrusion on log #2.
log installation MLDV Series Gas Fireplace 6. Place log #5 by matching the rectangular notch on the bottom of the log with the rectangular protrusion on log #2, then set the notch on the bottom of this log over the very far left tong on the grate. Figure 69 Log #5 Figure 69 Install Log #5 LG547 7. Place log #6 at an angle over log #5 toward LG547 the back by matching the rectangular notch MLDV log #5of this log with the rectanguon the bottom lar protrusion on log #5.
WARNING MLDV Series Gas Fireplace cleaning and maintenance Thermocouple Sensor Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Thermopile Burner, Pilot and Control Compartment Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
cleaning and maintenance Venting SysteM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. Glass Door Thoroughly clean the inside of the glass door after using the fireplace for ten hours. Periodically clean the glass door as necessary.
troubleshooting MLDV Series Gas Fireplace Standing Pilot Ignition MILLIVOLT SYSTEM SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not light pilot after repeated triggering of piezo. A. Wire disconnected. A. Open door and check to make sure wire is connected to ignitor. B. Check for spark at electrode and pilot. If no spark and electrode wire is properly connected, replace pilot assembly. C. Check remote/manual shut off valve from fireplace.
troubleshooting MLDV Series Gas Fireplace Standing Pilot Ignition MILLIVOLT SYSTEM SYMPTOM POSSIBLE CAUSE 4. Frequent pilot outage problem. A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame or too low, causing pilot impingement on thermocouple. safety to drop out 5. The pilot and main burner extinguish while in operation A. Inner vent pipe leaking exhaust gases back into system B. Horizontal vent improperly pitched C. Improper vent cap installation A.
troubleshooting MLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM OPERATION Install batteries and/or plug in the AC board FAULT No beep in about 8 seconds A Using battery? Make sure Command Center and the control board are connected by a 2 feet or 15 feet cable After the beep Flip the master switch (rocker switch) to the ON position Press the ON button on the Command Center No beep or no sound from the valve indicating pilot solenoid open B No sparking on the pilot C Sparking doesn’t continu
replacement parts MLDV Series Gas Fireplace firebox components and accessories 4 5 7 2 8 3 8 Item Description Qty. MLDV500 Standard Features 1. Junction Box Assembly (not shown) 75D0004 1 26D2128K 2. Control Cover 1 74D0119 MLDV parts 3. Glass Frame Assembly 1 75D1016 4. Insulation Board 1 75D0008 Accessories/Field Installed Options 5. Eyebrow 1 20302777 6. Decorative Mesh Glass Cover (not shown) 1 MLDV500SD 7. Firebrick Walls - Cottage Clay 1 FBMLDV500CC 7.
MLDV Series Gas Fireplace replacement parts LOGS Item 1. 2. 3. 4. 5. 6. 7. 56 Description Qty.
replacement parts MLDV Series Gas Fireplace STANDING PILOT - MILLIVOLT CONTROL 2I 1 2C 2T 2 5 4 6 3 8 9 7 10 11,12, 13, 14, 15 0004 MLDV control parts 75D0004 57
MLDV Series Gas Fireplace replacement parts Standing Pilot – Millivolt Control Item Description Qty. 1. Gas Valve Assembly 1 2. Pilot Assembly 1 2C. Replacement Thermocouple 1 2I. Replacement Igniter and Wire 1 2T. Replacement Thermopile 1 3. Burner Tube 1 4. Flex Hose w/Shutoff Valve 1 5. Rocker Switch 1 6. Piezo Igniter 1 7. Injector 1 8. Burner Assembly 1 9. Venturi 1 10. Wire Assembly 1 10. Wire Assembly 1 Accessories 11. Thermostatic Remote Control 1 12. On/Off Remote Control 1 13.
replacement parts MLDV Series Gas Fireplace SIGNATURE COMMAND SYSTEM 1 2 4 3 5 6 8 7 12 13,14,15,16,17 9 19 0004 SG parts 8/08 75D0004 59
MLDV Series Gas Fireplace replacement parts SIGNATURE COMMAND SYSTEM Ref. 1. 2. 3. 4. Description Qty. Gas Valve Assembly 1 Pilot Assembly 1 Control Box 1 Command Center 1 5. Burner Tube 1 6. Flexhose with Shutoff Valve 1 7. Injector 1 8. Burner Assembly 1 9. Venturi 1 10. Wire Valve/Control (not shown) 1 11. Wire Command Center Control Box 2 feet (not shown) 1 12. A/C Adapter (6 Volt) 1 Accessories 13. Hand Held Remote Control w/ HI/LO and Timer 14. Hand Held Remote Control w/ Hi/lo And Tstat 15.
VENTING COMPONENTS MLDV Series Gas Fireplace 1 7 4 8 9 HO T 5 2 3 6 11 10 0004 MLDV vent parts For more information about, or instructions for, the venting components referenced above, please contact the component manufacturer: Selkirk Corporation: www. selkirkcorp.com or 800-992-8368 Duravent: www. duravent.
MLDV Series Gas Fireplace VENTING COMPONENTS VENT COMPONENTS FOR 4" X 6B\," Current Old Duravent Duravent or Vermont or Vermont Qty./ Castings Group Castings Group Selkirk Item Box Description Part no. Part no. Part no.
VENTING COMPONENTS MLDV Series Gas Fireplace VENT COMPONENTS FOR 5" X 8" Current Old Duravent Duravent or Vermont or Vermont Qty./ Castings Group Castings Group Selkirk Metal-Fab Item Box Description Part no. Part no. Part no. Part no.
VENTING COMPONENTS MLDV Series Gas Fireplace HORIZONTAL VENTING - 4" x 7" Horizontal Vent Termination Kits Description Model Number Rear Vent Hot Touch Termination Kit w/ 10" to 16" 7TBRHTK Adjustable Termination Pipe, Firestop, and Hot Touch Termination w/ Siding Shield Up and Out Side Wall Termination Kit w/ 10" to 16" 7TDVSCTK Adjustable Termination Pipe, 90° Elbow, Firestop, and Cool Touch Termination w/ Siding Shield Rear Vent Cool Touch Termination w/ Siding S
VENTING COMPONENTS MLDV Series Gas Fireplace VERTICAL VENTING - 4" x 7" Description Vertical Vent Termination Kits Model Number Vertical Vent Termination w/ Storm Collar (flashing NOT included) 7TDVSKV Vertical Vent Termination w/ Storm Collar - 8 pack (flashing NOT included) 7TDVSKV/8 Vertical Vent Termination w/ 1/12 - 6/12 Flashing, Storm Collar and Ceiling Support Kit 7TDVSKVA* Vertical Vent Termination w/ 6/12 - 12/12 Flashing, Storm Collar and Ceiling Support K
MLDV Series Gas Fireplace Massachusetts Residents Only — Please read and follow these special requirements NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence.
MLDV Series Gas Fireplace Limited lifetime warranty policy Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
Based on CSA P.4.1-09 Efficiency Ratings Model MLDV500NV MLDV500PV EnerGuide Ratings Fireplace Efficiency (%) 70.5 76.4 D.O.E. (AFUE%) 67.1 67.3 Recherchez dans la brochure les caractéristique de rendement énergétique de foyer au gaz Énerguide Based CSA P.4.1-09 Selonon CSA P.4.1-09 Vermont Castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.