Operating instructions
12
51D0528
LX Series Direct Vent Gas Fireplace
Consult local building codes before beginning
the installation. The installer must make
sure to select the proper vent system for
installation. Before installing vent kit, the
installer must read this replace manual and
vent kit instructions.
Only a qualied installer/service person should
install venting system. The installer must follow
these safety rules:
• Wear gloves and safety glasses for protec-
tion.
• Use extreme caution when using ladders
or when on rooftops.
• Be aware of electrical wiring locations in
walls and ceilings.
The following actions will void the warranty on
your venting system:
• Installation of any damaged venting com-
ponent.
• Unauthorized modication of the venting
system.
• Installation of any component part not
manufactured or approved by Vermont
Castings Group.
• Installation other than permitted by these
instructions.
until
the flue penetrates the outside wall.
* A minimum of 3" clearance to the top is required along
horizontal length until ue pipe penetrates outside wall.
** A minimum 1" clearance to combustibles permitted all
around ue at outside wall
1"
*3"
**1"
**1"
35(6”
(911 mm)
FP2713
vent clearance
Figure 10 -
Combustible Clearances for Vent Pipe
FP2713