Operating instructions

44
20306743
KSTDV Series Gas Fireplace
CLEANING AND MAINTENANCE
VENT SYSTEM
The replace and venting system should be inspected
before initial use and at least annually by a quali ed eld
service person. Inspect the external vent cap on a regular
basis to make sure that no debris is interfering with the
air ow. Inspect entire venting system to ensure proper
function.
GLASS DOOR
Thoroughly clean the inside of the glass door after using
the replace for ten hours. Periodically clean the glass
door as necessary.
When cleaning the glass, remember:
Do not remove the glass when hot. Allow glass to
cool before removal.
NEVER use abrasive materials.
Keep children and pets a safe distance away.
Never operate the replace without the glass door
properly secured.
Never operate the replace if the glass is broken.
Replace any glass that is chipped, cracked, or broken.
Replacement glass door assemblies MUST be supplied
by the replace manufacturer No substitute materi-
als may be used.
Handle glass door with care to avoid striking or scratch-
ing it on hard objects.
To clean glass door, follow “Glass Removal” procedure
outlined in the Final Installation section. Film deposit on the
inside of the glass should be cleaned off using a nontoxic,
non-corrosive, non-abrasive, mild-cleaning solution. Simply
apply an adequate amount to the glass and wipe off with
a damp cloth. After all maintenance has been completed,
re-install glass door.
LOGS
Leave logs installed in the replace for cleaning. Vacuum
surface of the logs with a brush attachment. If logs must
be removed for cleaning, handle carefully by holding gently
at each end. Gloves are recommended to prevent skin irri-
tation from ceramic bers. If skin becomes irritated, wash
gently with soap and water. Vacuum surface of logs with
brush attachment or brush logs with a soft bristle brush (i.e.
clean, dry paintbrush). To place logs back in the replace,
see “Log Placement” found in the Final Installation section.
NOTE: Do not use uids to clean ceramic ber logs.
ROCK WOOL
Replace or add rock wool as required following installation
instructions in the Final Installation section of this manual.