Specifications

DFS Series Vent Free Fireplace
71D0532 7


Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented gas log grate/burner assembly
Installation/operating instructions
Ceramic ber logs
Rock wool
Plastic bag containing crushed volcanic rock
Trim kit
Canopy and ve (5) mounting screws
The millivolt controlled version of this heater is the only
style designed to be operated with optional devices for
ON/OFF functions. The following options may be used
with the millivolt controlled heater. These options are not
packaged with the log set.
Hand held remote with receiver
Wall switch with 15' wire
Wall thermostat with 15' wire
Hand held thermostat remote with receiver
    




Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance.



You must have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG and 1/2 lb.
natural gas systems only)
Piping which complies with local codes
Pipe wrench or appropriate size crescent wrench
set
Pipe sealant approved for use with propane/LPG
(Resistant to sulfur compounds)
Sediment trap
Manual shutoff valve
Tee joint.
Phillips head screwdriver








In planning the installation for the replace it is necessary
to determine where the unit is to be installed and whether
optional accessories are desired. Gas supply piping should
also be planned. The following steps represent the normal
sequence of installation. Each installation is unique, how-
ever, and might require a different sequence.
1. Position fireplace in desired location. Refer to the
“Location of Fireplace” and “Clearances and Height
Requirements,” and “Firebox Framing” sections found
in this manual. 

2. Install canopy and logs per instructions found in this
manual. The canopy MUST be installed for safe opera-
tion of the unit.
3. Field wire main power supply to units with fan kit.
Refer to the “Electrical Section” found in this manual.
(Electrical connections should only be performed by an
experienced, licensed certied tradesman).
4. Install optional ON/OFF kit on units with millivolt control.
Refer to installation instructions included with the kit and
also refer to the “Electrical Wiring” section found in this
manual.
5. Plumb gas line. Refer to the “Connecting the Gas” sec-
tion found in this manual. (Gas connections should only
be performed by an experienced, licensed / certied
tradesman).
6. Complete nish wall material and/or surround.

 
     





 
      
    
    
