Specifications

DFS Series Vent Free Fireplace
20
71D0532


       
In addition, periodically check the ames visually during
operation.

        
It should just touch the top of the
thermocouple tip for natural. Refer to Figure 24 for correct
pilot ame.
If the pilot ame does not touch the thermocouple, then
the main burner cannot function reliably. Refer to Figure
25 for incorrect shape of pilot ame.

FP2272
pilot correct flame
Thermocouple
for Natural Gas
Thermocouple
for LP
FP2272


FP2273
pilot bad flame
Thermocouple
for Natural Gas
Thermocouple
for LP
FP2273



In normal operation at full rate after 15 minutes, the follow-
ing ame appearances should be observed:
Burner will have a random pattern of yellow ames as
shown in Figure 26. There should be glowing embers on
the front burner. 

LG686
DFS log flames


LG686