Specifications
8
Vermont Castings Intrepid
®
III Multi-Fuel
30003891
Always adhere to local building codes when installing a
wall pass-through.
Figure 7 shows an alternate method of passig a con-
nector through a wall. All combustible material in the
wall is cut away to provide the required clearance that
is three times the pipe diameter. The resulting space
must remain empty. A flush-mounted sheet metal cover
may be used on one side only. If
covers must be used
on both sides, each cover must be mounted on noncom-
bustible spacers at least 5 mm (1”) clear of the wall.
ST247
Rear exit floor dgrm
12/14/99 djt
Wood framing requires pro-
tection form radiant heat
ST47b
Supporting timbers under fireplace hearth are consid-
ered to be combustible.
ST276
CSA approved wall
pass-through
12/99
460 mm (18”)
clearance all
around the pipe
4 ga. Sheet
Steel Support
(one side only)
ST76
An approved wall pass-through.
Chimney Clearance
to Sheet Steel Sup-
ports and combus-
tibles
51 mm (”) Min.
Min. 460 mm
(18”)
Chimney
Connetor
4 ga.
Sheet Steel
Support
Masonry Chimney
This appliance must be installed on to hearth that
meets the requirements of Part J of the Building Regu-
lations 000 (Combustion Appliances and Fuel Storage
Systems). This can be achieved by ensuring that the
hearth is constructed and sized in accordance with the
guidelines included in section of approved document
‘J’. The size and clearances of the hearth are as fol-
lows:
The constructed hearth should be constructed in ac-
cordance with the recommendations in document J,
and should be of minimum width 840 mm and minimum
depth 840 mm (if a free standing hearth b) above) or
a minimum projection of 150 mm from the jamb (if a
recessed hearth a) above).
Do not assume your fireplace hearth is completely
noncombustible.
Many fireplace hearths do not satisfy the “completely
noncombustible” requirement because the brick or
concrete in front of the fireplace opening is supported
by heavy wood framing as in Figure 8. Because heat
passes through brick or concrete readily, it can easily
pass through to the wood. As a result, such fireplace
hearths can be a fire hazard and are considered a com-
bustible floor.
Keep in mind that many raised hearths will extend
less than the required clearance from the front of the
heater when it is installed. In such cases, sufficient
floor protection as described above must be added in
front of the hearth to satisfy the minimum floor protector
requirement from the front of the stove: 406 mm (16”)
from the front. Fireplace hearths must also offer the
required protection of 15 mm (6”) on either side.
Optional 76 mm (3”) short legs may be used only on
such hearths that meet the width and depth require-
ments outlined previously under “floor protection.”
Hearth rugs do not satisfy the requirements for floor
protection.