Specifications
4
Vermont Castings Intrepid
®
III Multi-Fuel
30003891
Before you begin an installation, review your plans to
see that:
• Your stove and chimney connector will be far
enough from combustible material to meet all clear-
ance requirements.
• The floor protector is large enough and is construct-
ed properly to meet all requirements.
• You have all necessary permits from local authori-
ties.
Your local building official is the final authority for ap-
proving your installation as safe and determining that it
meets local and state codes.
The metal label permanently attached to the back of ev-
ery Vermont Castings stove indicates that the stove has
been tested to current standards. The test standards
are UL 148 and UL 737 for the US and EN1340:001
+ A:004 for Europe. Clearance and installation infor-
mation also is printed on the label. When the stove is
installed according to the information both on the label
and in this manual, local authorities in most cases will
accept the label as evidence that the installation meets
codes and can be approved.
However, codes vary in different countries. Before
starting the installation, review your plans with the local
building authority. You local dealer can provide any ad-
ditional information needed.
In some modern, super-insulated homes, there is not
enough air for combustion because of insufficient air
infiltration into the building. Such air enters a home
through unsealed cracks and openings. Kitchen or bath
exhaust fans can compete with the stove for available
air and compound the problem.
When poor draft is caused by a low infiltration rate,
opening a ground floor window on the windward side
of the house and in the vicinity of the stove will usually
alleviate the problem.
Another solution is to install a permanent outside air
supply to the stove and/or room. In some areas, in
fact, bringing air for combustion from outside the home
directly to the air inlet of the stove is required for new
construction.
An outside air supply is not affected by pressure varia-
tions within the house, and improved stove perfor-
mance often results. An Outside Air Adapter Kit #3358
for the Intrepid is available from your local Vermont
Castings dealer.
Your Intrepid Multi-fuel must be connected to a code-
approved masonry chimney with a flue liner, to a relined
masonry chimney that meets local codes, or to a pre-
fabricated metal chimney. Whatever kind you use, the
chimney and chimney connector must be in good condi-
tion and kept clean. Figure shows the two chimney
types.
ST241
chimney types
12/13/99 djt
A prefabricated double-
wall insulated chimney
A tile-lined
masonry
chimney
ST41
Standard chimney types.
If you use an existing masonry chimney, it must be
inspected to ensure safe condition before the stove is
installed. Your local professional chimney sweep, build-
ing inspector, or fire department official will be able to
inspect the chimney or provide a referral to someone
who can.
The flue and chimney design must meet requirement
J, Part J of the building regulations 000 (Combustion
Appliances and Fuel Storage Systems).