Specifications

5
Vermont Castings Intrepid
®
III Multi-Fuel
30003891


1. The damper assembly is retained by two tab bolts.
These must first be loosened from both sides of the
upper rear face of the stove.
. When loosened, rotate the two tab bolts from inside
the stove to release the damper assembly. Carefully
remove the damper retaining plate.
34
LOOSENBOLTS

ST906
 Loosen damper assembly bolts.
34
REMOVEDAMPERRETAININGPLATE

ST907
 Remove the damper retaining plate.
3. Carefully remove the damper plate.
4. Remove the outer firebrick followed by the inner
firebrick.
5. With both vertical fire bricks removed the secondary
combustion chamber can be thoroughly cleaned out,
then if required the base firebrick can be removed.
6. Reassemble in the reverse sequence, taking care to
ensure that the front and rear vertical firebricks are
correctly positioned to allow the flue gases to pass
between.
34
REMOVEDAMPERPLATE

ST908
 Remove damper plate.
34
REMOVEFIREBRICK

ST909
 Remove outer and inner firebrick.
34
CLEANINSIDE

ST910
 Inside of stove can now be cleaned thoroughly.
3T
REMOVESECONDARY
COMBUSTIONCHAMBER
FIREBRICKS

Rear Vertical
Firebrick
Gap for
Passage of
Combustion
Gases
Front Vertical
Firebrick
ST889
 Remove vertical firebrick.