User`s guide
System Administrator
117
A
Perform Incrementals
Based on Archive Bit:
This parameter should be changed only by a system administrator.
Select this check box to have NetBackup include files in an
incremental backup only if their archive bit is set. The system sets
this bit whenever a file is changed and it will remain set until
NetBackup clears it. A full backup always clears the archive bit. A
differential-incremental backup clears the archive bit if the file is
successfully backed up within the number of seconds indicated by
Clear_Archive_Bit_Incr_Wait. A cumulative-incremental
backup or user backup has no effect on the archive bit.
Clear this checkbox to have NetBackup include a file in an
incremental backup only if the file’s datetime stamp has been
changed since the last backup. For a differential-incremental
backup, NetBackup compares the file’s timestamp against the last
full backup. For a cumulative-incremental backup, NetBackup
compares the timestamp against the last full backup or
incremental backup.
If you install or copy files from another computer, the new files
retain the datetime stamp of the originals. If the original date is
before the last backup date on this computer, then the new files
will not be backed up until the next full backup.
Windows 95/98 and Windows NT clients use the create and
modify datetime stamp.
Allow Server-Directed
Restores:
This parameter should be changed only by a system administrator.
Select this check box to let the administrator on the NetBackup
server initiate restores to this client. The default is to allow server
directed restores.
Perform Default
Search:
If selected, NetBackup will automatically search the default range
of backup images and display the backed up folders and files
whenever a restore window is opened.
Clear this box to disable the initial search. The NetBackup Restore
window will not show any files or folders when initially opened.
Clicking a backup image, or selecting a range of backup images,
will initiate a search.
By default, this box is selected.
OK
To accept changes to the parameters, click this button.