User Manual

7
AFS 6”Sch40 150 SS 4” 05 H R C2NC H2 XP For Transmitter Selection, see Page 8.
Model Accelabar 316SS
AFS Flanged Connections
ABS Bevel for Weld
User Mating Pipe Size and Schedule or Exact ID and Wall Thickness
Code User Mating Flange (Model AFS Only)
150 150# ANSI Class 275 psig @ 100°F, 80 psig @ 800°F (19 Bars @ 38°C, 5.5 Bars @ 426°C)
300 300# ANSI Class 720 psig @ 100°F, 330 psig @ 800°F (49.6 Bars @ 38°C, 22.8 Bars @ 426°C)
600 600# ANSI Class 1440 psig @ 100°F, 660 psig @ 800°F (99.3 Bars @ 38°C, 45.5 Bars @ 426°C)
If other than ANSI, specify Standard (DIN, JIS) Size and Rating
Code Flange Material
C Carbon Steel
S Stainless Steel
Accelabar Meter Size
Important: If the selected meter size is larger or smaller than the
user’s mating pipe and flange, expanders or reducers are required.
Consult the factory for price and delivery.
3” 4” 6” 8” 10” 12”
(75mm) (100mm) (150mm) (200mm) (250mm) (300mm)
Code Verabar Size
05 7/16” (11mm)
10 7/8” (22mm)
Code Pipe Orientation
H Horizontal
V Vertical
Instrument Head Connections
(Select Remote or Direct Mount TransmitterSold Separately)
Direct Mount Transmitter Remote Mount Transmitter
(Flanged 450°F/232°C Max.) (1/2” NPT)
Manifold Transmount Valve Regular Parallel
MF T RP
Code RTD in Thermowell
H1 Hazardous Location, Class 1 Div 1, Explosion Proof
H2 Hazardous Location, Class 1 Div 2, Non-Incendive Wiring
HT High Temperature (500ºF to 900ºF, 260ºC to 482ºC)
NH Non-Hazardous Location
Code Connection Cable to Transmitter
(Direct Mount Only)
XP Explosion Proof (hazardous locations)
N4 NEMA 4
Manifolds
(Optional)
Instrument Valves
(Optional)
Direct Mount Remote Mount
3-Valve 5-Valve Needle Gate
F3SC(CS) F3HC(CS) F5SC(CS) F5HC(CS) C2NC(CS) C2GC(CS)
F3SS(SS) F3HS(SS) F5SS(SS) F5HS(SS) C2NS(SS) C2GS(SS)
Soft Seat Hard Seat Soft Seat Hard Seat
1/2” NPT
1/2” NPT
Integral Integral
Optional
Optional
Optional