[OPEN] key.
4. Move the joystick up/down to choose ON or OFF.
5. Press the [OPEN] key to confirm the selection or press the [CLOSE] key to
cancel selection and exit from the menu screen.
► To set Set the Manual Scan Range:
1. Activate the manual scan range (MANUAL LIMIT STOP = ON) and then exit
the menu.
2. Set the left limit: use the joystick and move the camera to the left limit
position, then press number key “90” + hold the key for 2 seconds. The
screen will show: MANUAL LEFT LIMIT, and the left limit will be set.
3. Set the right limit: use the joystick and move the camera to the right limit
position, then press number key “91” + hold the key for 2 seconds. The
screen will show: MANUAL RIGHT LIMIT, and the right limit will be set.
Setting Recover Time
<PAN/TILT SETUP> → RECOVER TIME
Under scan mode (auto, frame, random), if the auto patrol and pattern patrol
are interrupted from inadvertent keypad controller input, the camera will
resume the previous action after a set amount of time. The recovery time can
be configured from 1 to 120 min, and can be disabled (OFF).
► To set the Recovery Time:
1. Press “95” + hold the [PRESET] key for 2 seconds to enter the main menu
screen.
2. Move the cursor to <PAN/TILT SETUP>, and then press the [OPEN] key
<PAN/TILT SETUP> menu.
3. Move the cursor to the RECOVER TIME selection and then press the [OPEN]
key.
4. Move the joystick up/down to set the time.
5. Press the [OPEN] key to confirm the selection or press the [CLOSE] key to
cancel selection and exit from the menu screen.
Setting Scan Speed
<PAN/TILT SETUP> → SCAN SPEED
Auto, random, and frame scan speed can be configured between 1° ~ 90° /sec,
but cannot exceed the MAX SPEED setting.
Chapter 4: Configuring the Nextiva S5500 PTZ Series Properties
© 2013 Verint Video Systems Inc. 85