User guide

DIP Switch Settings
The factory default DIP switch settings are SW1: 1 is ON, and SW2: 3, 4, 7 and
8 are ON.
SW1 sets the PTZ address.
SW2 sets the protocol/baud rate and termination resistor.
The factory default values are:
PTZ Address is set to 1
Protocol is set for Pelco-D. (DIP switches 3 and 4 are ON.)
Baud rate is set for 2400 bps. (DIP switches 7 and 8 are ON.)
Termination resistor is off. (DIP switch 2 is OFF.)
Note
In an IP only configuration, the DIP switch settings do not need to be modified.
However, if you are using a hybrid (Serial-IP) configuration and change the
DIP switch settings, you need to set the Protocol and PTZ address values in
Nextiva VMS to match the value of the DIP switch in order to control the PTZ
IP camera.
Appendix 5: Technical Specifications
© 2013 Verint Video Systems Inc. 103