Instruction manual

BOOT MODE FUNCTIONS
LinkPoint International, Inc.
1999 15 LFRST23 Reference Manual
RS232 Port Setup
To change the RS232 port factory defaults follow the steps outlined below. The default settings
are designed to be used for direct RS232 and Master-Slave (POS-to-POS) downloads. Standard
Default: Baud= 19200, Parity= None.
There is usually no need to change these settings
.
Display Message Operator Action
READY XXX Hold down the [ALPHA] key and press [7] [1] [3] [9]. Release
JAN-03-00 _MON _12:00P the [ALPHA] key to enter the boot mode.
[
] [
] [
]
CLEAR_to_resume Press the right [
] key to select SETUP.
_ Time Load Setup
[
] [
] [
]
Setup Press the left [
] key to select PORTS.
Ports Model Test
[
] [
] [
]
Port setup Press the middle [
] key to select RS232.
Printer RS232 Pinpad
[
] [
] [
]
RS232 setup Press the left [
] key to select BAUD.
Baud Parity
[
] [
] [
]
Current baud: 19200 Select the correct baud rate (default is 19200). Press the [#]
1200 2400 9600 key to see other options. Press the [
] key below your choice
[
] [
] [
] to select it and press [CLEAR].
RS232 setup Press the right [
] key to select PARITY.
Baud Parity
[
] [
] [
]
Current parity: None Select the correct parity (default is None). Press the [
] key
Even None Odd below your choice to select it and press [CLEAR] five times
[
] [
] [
] to reboot the terminal.