User's Manual
5
Verge Inc – VA-A-10049 Module Integration Guide – rev1.0
Integration
The VA-A-10049 module is designed to be plugged directly into a Samtec HSEC8-125-01-L-DV-A-K-
TR card-edge connector, assuming a valid pin matrix. An integrating system must provide a
regulated +3.3VDC rail capable of supply up to 100mA of current. The system must include a host
controller capable of communicating with the AT86RF215 radio over an SPI bus, and must be
capable of communicating with the 24AA025E64 EEPROM over I2C.
+3.3VDC, 100mA supply
Host controller
o SPI Bus
o I2C Bus
The host controller must run proprietary software written and distributed by Verge Inc. and its
affiliates for controlling the transceiver.