TDS
Effective: January 4, 2024
VERGE PRO
TECHNICAL DATA SHEET
PHYSICAL PROPERTIES & PACKAGING (DRYBACK/GLUE-DOWN LUXURY VINYL TILE FLOORING – 2.5 MM / 0.5 MM)
Use Commercial & Residential Commercial & Residential
Size
12 x 12 in. (304.8 x 304.8 mm) 7 x 48 in. (177.8 x 1219.2 mm)
Thickness - Overall 2.5 mm (0.098 in.) 2.5 mm (0.098 in.)
Thickness - Wear Layer 0.5 mm (20 mil) 0.5 mm (20 mil)
Profile Square Edge Square Edge
Finish Urethane with Ceramic Bead Urethane with Ceramic Bead
Embossing Satin Semi Wild
Coverage - Carton 36 Pieces/Carton (36 Sq.Ft. / 3.34 Sq.M.) 18 Pieces/Carton (42 Sq.Ft. / 3.90 Sq.M.)
Coverage - Pallet 63 Cartons/Pallet (2,268 Sq.Ft. / 210.7 Sq.M.) 50 Cartons/Pallet (2,100 Sq.Ft. / 195.0 Sq.M.)
Coverage - Container 18 Pallets/Container (40,824 Sq.Ft. / 3,792 Sq.M.) 20 Pallets/Container (42,000 Sq.Ft. / 3,901 Sq.M.)
Limited Warranty 20-Year Commercial / Lifetime Residential 20-Year Commercial / Lifetime Residential
STANDARDS – MANUFACTURING & USAGE (ASTM F1700)
Standard Description Requirements Results
ASTM F1700
Classification Refer to Standard Class III, Type B
ASTM F1700 Physical Characteristics / Tolerances Refer to Standard Passes Requirements
1
ASTM F1914 Residual Indentation Average <8%; Any Sample ≤10% Passes Requirements
ASTM F137 Flexibility No cracks/breaks (1 in./25.4 mm mandrel) Passes Requirements
ASTM F2199 Dimensional Stability ≤0.020 in./Linear Foot Passes Requirements
ASTM F925 Chemical Resistance No more than “Slight Change” Passes Requirements
ASTM F1514 Resistance to Heat Average ΔΕ < 8.0 Passes Requirements
ASTM F1515 Resistance to Light Average ΔΕ < 8.0 Passes Requirements
STANDARDS – SAFETY & PERFORMANCE
Standard Description Requirements Results
ASTM E648
Critical Radiant Flux (Radiant Panel) Class I: ≥ 0.45 W/Sq.cm. Passes Requirements
2
ASTM E662 Smoke Density Flaming & Non-Flaming ≤ 450 Passes Requirements
3
CDPH Standard Method v1.2 VOCs/TVOCs, Formaldehyde Refer to Standard Passes Requirements
REACH SVHC 235 Substances of Very High Concern Per Substance: ≤ 0.1% Passes Requirements
ASTM F963 Heavy Metals Refer to Standard (Table I) Passes Requirements
CPSC-CH-C1001-09.4 Phthalates Per CPSIA
4
: ≤ 0.1% per Substance Passes Requirements
ASTM D2047 Coefficient of Friction / Slip Resistance N/A (No Official Requirements) ≥ 0.6 (Dry)
ANSI ESD STM97.2 Body Voltage N/A (No Official Requirements) Average (Abs) ≤ 2.0kV
ASTM F970 Static Load N/A (No Official Requirements) 0.005 in., 1500 psi
ASTM D4060 Abrasion Resistance N/A (No Official Requirements) 62,000 cycles
STANDARDS – SOUND
Assembly ASTM E90 ASTM E492 ASTM E2179 Results (Remarks)
6-inch Concrete Slab
STC 51 IIC 50 ΔIIC 14
Tested assemblies (include separate underlayment)
pass International Building Code (IBC) requirements
of STC ≥ 50 and IIC ≥ 50 for multi-story dwellings.
6-inch Concrete Slab + Drop-Ceiling STC 61 IIC 66 Not Applicable
Notes
1) ASTM F1700 - Physical Characteristics / Tolerances: includes Size, Squareness, Thickness, Wear Layer Thickness (Commercial Classification).
2) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code.
3) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes in the United States, but is not set as a limit for (resilient)
flooring products nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction.
4) CPSC-CH-C1001-09.4 - Phthalates: CPSIA = Consumer Product Safety Improvement Act.