User`s guide

282 Verex Director V4.9.1 User's Guide 21-0381E v4.9.1
Area (if event occurs in a specific area):
A
rea Function key #0, #1, ...#9
(Pertains to keypad functions keys)
A
rea On
When the area is fully armed (ON).
A
rea Stay 2 (future use)
When the arming level is STAY 2 (future)
A
rea Stay 1
When the arming level is STAY.
A
rea Stay (1 or 2)
When armed to STAY. (Stay 2 = future)
A
rea Off
When the arming level is OFF
A
rea Not On
When the arming level is "Off" or "Stay".
A
rea Not Off
When the arming level is "Stay" or "ON".
A
rea
A
larm
When area is in ALARM. Resets when
point(s) restore or follows siren timeout
(includes pseudos & tampers)
A
rea Was In Alarm
When area WAS IN ALARM. This is only for
input points in alarm e.g. NOT for system
trouble (clears when alarmed areas are
turned off then back on again)
A
rea Siren Fire (1 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 1 sec ON/OFF for
FIRE
A
rea Siren Fire (2 sec.)
Follows ALARM siren - steady for BURG /
EMERG and provides 2 sec ON/OFF for
FIRE
A
rea Sonalert (E/E tones on Stay)
Follows sonalert, chime & provides Entry/Exit
tones when armed to STAY & ON
A
rea Sonalert (No E/E tones on Stay)
Follows sonalert, chime & does not provide
Entry/Exit tones when armed to STAY but
provides Entry/Exit tones in ON
A
rea Extended Delay Entry Tones
Follows Garage/extended delay Entry Tones
A
rea Bypasses
When any point in this area is BYPASSED
A
rea Fire
When any ‘FIRE’ type point in this area is in
alarm
A
rea Hold-Up
When any ‘HOLD UP’ type point in this area
is in alarm
A
rea
A
uxiliary Alert
When any ‘AUXILIARY ALERT’ type point in
this area is in alarm.
A
rea Vault
When any ‘VAULT / SAFE’ type point is in
alarm.
A
rea Burglary
When any ‘BURGLARY’ type point in this
area is in alarm.
A
rea Supervisory
When any ‘Supervisory' point is in alarm.
A
rea Pseudo
When any 'Pseudo' condition is in effect.
A
rea Walk Test
A
rea is in ‘Walk’ or ‘Hold-up’ test.
A
rea Entry / Exit
When area Entry / Exit delay is in progress –
provides a steady output (STAY & ON).
A
rea Entry
When area Entry delay is in progress -
provides a steady output (STAY & ON).
A
rea Exit
When area Exit delay is in progress -
provides a steady output (STAY & ON).
A
rea Ready
When the area is ‘Ready To Arm’ - i.e. all
points are secure.
A
rea Open Window
When the active/open window of the area's
schedule is in effect.
A
rea Closing
When the area schedule is expiring in 15
minutes.
A
rea Door Unlocked
A
rea Door Locked Out
A
rea Door Held Open
A
rea Door Forced
A
rea Door Tamper
Door Tampers (door contact condition: no
EOL resistor etc.)
A
rea Door Open
A
rea Door Secure
A
rea Door Sensor Trouble
Door Sensor Troubles (magnetic bond
sensor not ok)
A
rea Panic Token Detected