System Overheat Temperature:
Enter a value for the thermal monitor trip point. If the system temperature is ex-
ceeded for more than 1 minute, the system will be shut down automatically. Click
‘Apply’ when finished.
Automatic Power Recovery:
If this feature has been enabled and the electric power is cut off or the system can-
not complete a normal power off, the system will power on automatically when
power is restored. Click ‘Apply’ when finished.
Schedule Power On/Off:
You can set what time you
want to shut down the
PowerBay NAS array or to
power on the PowerBay
NAS array. Use ‘Mode’ to
disable it or enable it.
When Schedule Power On/
Off Mode is set to Days
of Week, you can ll in the
table presented to dene
on/off times for each day
independently. Click Apply
when nished.
Firmware - Page
The PowerBay NAS array Firmware menu allows you to install new firmware re-
leases for the device.
Firmware:
You can upgrade
the firmware of the
device from this
page. The firmware
file you want to
use must be saved
on the local hard drive of the computer you are working from. Click on ‘Browse’ to
search the local hard drive for the firmware file to be used for the update. Click ‘Up-
grade’ to begin the upgrade. Please wait a few minutes for the file to download fully
and for the unit to return to the standby power state. You will then be prompted to
pull out the power plug, to reinsert the power plug and then to power on the unit to
complete the upgrade process.