www.ventilation-system.com
150
150
35
ø106
305 – 380 (700*)
TECHNICAL DATA
The temperature in the room where the indoor unit of the ventilator is installed must be in the range from +1 ˚C to +40 ˚C with relative
humidity up to 65 % (no condensation build-up). If the conditions for using the ventilator are beyond the specified limits, turn off the
ventilator. Provide fresh air supply through windows.
The transported air temperature must be in the range from -15 ˚C to +40 ˚C.
The ventilator is rated as a class II electric appliance.
Ingress protection rating against access to hazardous parts and water ingress is IP24.
The unit design is constantly being improved, thus some models may be different from those described in this manual.
The technical data of the specific model are indicated on the label on the ventilator casing.
The figure below shows the overall dimensions of the indoor unit of the ventilator and the minimum wall thickness sufficient for mounting
the internal components of the ventilator inside the air duct.
Ventilator model
Dimensions [mm]
Overall
dimension A
Air duct diameter D
Diameter of the hole in the wall for
mounting the ventilator D1
Minimum possible wall
thickness L
Solo RA1-35-9 R
Solo RA1-35-9 R V.2
150 106 120 – 125 305
Solo RА1-50-9 R V.2 175 131 145 – 150 325
Solo RА1-60-9 R V.2 205 156 170 – 175 355