BEFORE PERFORMING ANY MAINTENANCE ALWAYS ENSURE THAT THERE IS NO POWER TO THE FAN,
YOU MUST DISCONNECT THE ELECTRICITY AT THE MAIN POWER SOURCE!
Annually:
1) Check to make sure the bolts are tight.
2) Check impeller for dirt or other matter. Clean if necessary.
To clean, remove the four screws that secure the grille to the metal case.
Remove the grille from the case and clean the blades with warm, soapy water. Avoid splashing
water on the motor.
Wipe surfaces dry.
Also clean the inside of the metal case while you are at it.
Re-attach the grille to the case.
• Electrical wiring should only be done by a quali ed electrician.
Warranty will not cover equipment damage or failure that is caused by improper installation.
• If the fan did not come pre-wired or if a new wire is to be used, wire the fan as shown in the Figure
6 below.
• Use 18 AWG or greater wire.
WIRING THE FAN
Fig. 6
Bucket Fan 420 Bucket Fan Whisper 420
1.0 A
Bucket Fan 1055 Bucket Fan Whisper 1055
1.0 A
Bucket Fan 1460 Bucket Fan Whisper 1460
2.0 A
C1
X1
BLACK (LINE)
GREEN (PROTECTIVE EARTH)
WHITE (NEUTRAL)
Motor run capacitor
Motor terminal box
~120 VAC 60 Hz
MAINTENANCE