USER’S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 Bucket Fan Whisper 420 Bucket Fan Whisper 1055 Bucket Fan Whisper 1460
Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT’S INCLUDED IN THE BOX 3 DESIGNATION KEY EXAMPLE 3 SIZE RANGES 3 SAFETY REQUIREMENTS 4 MOUNTING AND INSTALLATION GUIDELINES 5 BUCKET FAN PARTS 7 MAINTENANCE 8 WIRING THE FAN 8 TROUBLESHOOTING 11 STORAGE 11 WARRANTY 12
INTRODUCTION This manual will provide you with installation, operation, and service instructions, as well as technical data of the Bucket Fan series and Bucket Fan Whisper series. USE Bucket Fans are used for equalizing the floor-to-ceiling temperature. This provides a more comfortable thermal environment for occupants, while at the same time reducing energy costs. In the cold months the overheated air at the roof is gently directed to the floor where it is needed and wanted.
Bucket Fan BUCKET FAN WHISPER BUCKET FAN Fig. 1 SAFETY REQUIREMENTS During installation and operation, observe all codes and safety standards for your locale. Always make sure the electricity is disconnected at the main power source prior to connection, adjustment, servicing and/or repair operations. Electrical connections should only be done by a qualified electrician.
MOUNTING AND INSTALLATION GUIDELINES Prior to Installation: Read and understand this entire manual. Should you have any questions before, during, or after installation please call your seller or contact VENTS at 888-640-0925 or install@VentsUS.com. Check the product for any damage that may have occurred during shipping. Rotate the impeller by hand to ensure it turns smoothly. Mounting The Bucket Fan comes with a set of Hanging/Safety Cables with Gripples.
Bucket Fan Tip: It is easier to attach the Hanging Cable and Gripple to the structure first and then attach the fan with the toggle. 1) Insert the cable into one of the openings in the Gripple 2) Place the cable over the I-beam, truss, or other structure from which it is being hung. 3) Insert the end of the cable into the other opening in the Gripple. 4) Adjust to desired height 5) Insert toggle into the top hole on the handle.
The Bucket Fan can be angled if needed. All it takes is a 13 mm socket wrench. Loosen the bolts on either side of the fan, place at the angle you want, then re-tighten the bolts. Fig. 4 1 BUCKET FAN PARTS Bucket Fan 4 1) Electrical junction box on protective grille. 2) Vibration absorbing mount 3) Metal case 4) Handle 5) Handle bolts 6) Casing 7) Sound-Insulation Layer 8) Airflow Straightener 9) Wing Head bolt 5 2 3 Bucket Fan Whisper 9 6 7 8 Fig. 5 The destratificator (see Fig.
Bucket Fan MAINTENANCE BEFORE PERFORMING ANY MAINTENANCE ALWAYS ENSURE THAT THERE IS NO POWER TO THE FAN, YOU MUST DISCONNECT THE ELECTRICITY AT THE MAIN POWER SOURCE! Annually: 1) Check to make sure the bolts are tight. 2) Check impeller for dirt or other matter. Clean if necessary. • • To clean, remove the four screws that secure the grille to the metal case. Remove the grille from the case and clean the blades with warm, soapy water. Avoid splashing water on the motor. Wipe surfaces dry.
CONTROLLER WIRING AND INSTALLATION • The following is for the installation of one controller for one fan. Contact VENTS US if you need to operate two or more fans with one controller. • Refer to Figure 7 for electrical connections. • Use 18 AWG or greater wire. • It is important that the controller be properly grounded for effective fan operation and personnel safety. • Always install the controller in sight of the fan it controls.
Bucket Fan 1. Application a) Motor Type – Shaded Pole, P.S.C. and Universal. b) Required Load – Fans, Blowers and Speed Dependent Loads. 2. Wiring Warning! Power must be turned off before wiring. Connect control in series with motor and line voltage; never connect control across line. Ground (Earth)** – Be sure to ground the control using the green wire. **Some models do not require grounding, therefore, a ground wire is not provided. 3. Mounting a) Use 2” deep standard electrical box.
Connection Diagram 2-Wire* Controls for No Switch Model (NS) Connection Diagram for 2-Wire* Controls (Switch Models) L1 L1 Switch Triac AC Line Green Green Triac AC Line Motor Motor Ground (Earth)** Ground (Earth)** L2 L2 Connection Diagram for 4-Wire* Controls Connection Diagram for 3-Wire* Controls (Switch Models) Full Voltage Black Blue*** AC Line Green Switch Ground (Earth)** L2 L1 Triac Auxiliary Load Red Black Variable Voltage 240 Volt Red L2 Motor Red Motor Blac
Bucket Fan WARRANTY VENTS US warrants to the original purchaser of the Bucket Fan Series series fan that it will be free from defects in materials or workmanship for a period of 60 months from the date of original purchase. If the fan is installed with the speed controller the warranty period is decreased to 24 months. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.