Technical Specifications
PRODUCT
SPECIFICATIONS
2013-10
TECHNICAL
DATA
Tel: 888-640-0925
513-348-3853
Fax: 513-268-4597
Sales@ventsus.com
VentsUS.com
11013 Kenwood Road, Cincinnati,
Ohio 45242
MODEL QUANTITY COMMENTS PROJECT
location:
architect:
engineer:
contractor:
submitted by:
* The parameters RPM, Watts are indicated at 0.2 in. WG static pressure.
PERFORMANCE
VK
INLINE CENTRIFUGAL FAN
Outline of
label;
printed line
is optional.
Model
Duct
dia
Sones RPM
*
Watts
*
CFM vs. Static Pressure (Ps) in WG
Volt / Hz
0” 0.125” 0.2” 0.25" 0.375" 0.5” 0.75" 1.0” 1.25" 1.5”
VK 100
4” 8.5 3088 106
162 155
150 147 141 134 120 104 87
67 120 / 60
VK 125
5” 7.1 2960 114
235 222 214 207 193
178 151 123 99
72 120 / 60
VK 150
6”
7.2 2907 113 317 300 289 282 265 247 212 178 132 68 120 / 60
VK 200
8”
8.1 3016 140 507 481 465 455 423 395 343 287 238 189 120 / 60
VK 250
10”
10.2 2604 293 735 699 675 658 625 558 507 432 369 307 120 / 60
VK 315
12
3/8
” 11.5
2641
269
871 817 779 758 703 635 501 393 324 266 120 / 60