MOUNTING AND SET-UP
READ THE USER’S MANUAL PRIOR TO MOUNTING THE UNIT.
DO NOT BLOCK THE AIR DUCT OF THE INSTALLED UNIT WITH DUST ACCUMULATING
MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT PREVENTS AIR
CIRCULATION IN THE ROOM.
1. Prepare a round core hole in the outer wall. The hole size is shown in the figure below. While preparing a core hole it is recommended
to make preparations for layout of the power cable and other required cables.
Ø 180
Ø 7
1
/
16
"
min 500
min 19
11
/
16
"
min 500
min 19
11
/
16
"
min 500
min 19
11
/
16
"
A
A
A-A
2. Insert the air duct in the wall. For ease of installation use the polystyrene wedges included in the delivery. The air duct end must
protrude for the distance that enables installation of the outer ventilation hood (see the User’s manual for the outer ventilation hood).
0 - 3 mm
(0 - 1/8")
Fill the gaps between the air
duct and the wall with
a mounting foam
A
Polystyrene wedge
min 3 mm
Insert the air duct into the wall as shown in the picture on the
left.
Install the air duct with the minimum slope of 3 mm down from
the outer wall side.
On the outer wall side the air duct end must protrude to a
distance that enables installation of the outer ventilation hood.
Distance A is stated in the installation instruction for the
ventilation hood.
Adjustment of the air duct length is possible before and after
its fixation in the wall.
In the first case calculate the required length before mounting
and in the second case be sure to have enough access to cut the
air duct length after its installation.
3. Stick the delivered cardboard master plate on the indoor wall using a mounting tape.
The large opening in the master plate must be axially aligned with the air duct.
For aligning of the master plate with respect to the horizon line it is recommended to use a builder’s level.
Then mark the fastening holes for installation of the supplied dowels and drill the holes to a required depth.
Route the power cable from the ventilator outside through the specially marked opening on the master plate.