SINGLE-ROOM ENERGY RECOVERY VENTILATORS TWINFRESH EXPERT RW1-85-2 V.
SINGLE-ROOM ENERGY RECOVERY VENTILATORS TwinFresh Expert is a new series of single-room energy recovery ventilators TwinFresh Expert is the most state-of-the-art and efficient solution for a comfortable indoor climate and required air exchange in renovated premises, brand new recently inhabited houses or reconstructed apartments. Features of TwinFresh Expert RW1-85-2 V.2 ventilators ontrolled by Android or iOS smartphone through the cloud server from any part of C the world.
www.vents-us.com Reversible DC fan Air is supplied or exhausted by a reversible axial fan with DC motor. Due to DC technology the fan has outstanding low energy demand. The fan is powered by safe voltage 12 V. The motor has integrated overheating protection and ball bearings for long service life.
SINGLE-ROOM ENERGY RECOVERY VENTILATORS Operation of TwinFresh ventilators The ventilator is designed both for reversible mode with energy regeneration and supply or exhaust mode with no regeneration. CYCLE I. Warm stale air is exhausted from the premise, flows through the ceramic regenerator and transfers up to 70 % of the accumulated heat and moisture to it. As the ceramic regenerator gets warmed up, the ventilator switches to the supply mode. CYCLE II.
www.vents-us.com Control Connection of several ventilators via Wi-Fi for synchronous operation. Ventilation control via cloud service worldwide. Connection to Smart Home or BMS via Wi-Fi. DUO units in a bathroom and kitchen Vents Cloud secondary Smart House secondary Regular units in a bedroom and living room primary secondary secondary secondary The app is available on the App Store and Google Play. 5 VENTS. SINGLE-ROOM ENERGY RECOVERY VENTILATORS l TWINFRESH EXPERT RW1-50-2 V.
SINGLE-ROOM ENERGY RECOVERY VENTILATORS Mounting The ventilator is designed for through-the-wall installation inside a prepared hole in an outer wall of the building. The best ventilation solution is pairwise installation of reverse phase connected ventilators when some units ensure supply of fresh air to the room and the other units exhaust air from the premise. This way the most efficient balanced ventilation is arranged. In case of brand new construction, the ventilators are mounted in two stages: 1.
www.vents-us.com Technical data Model TwinFresh Expert RW1-85-2 V.2 Speed 1 2 Voltage / 50 (60) Hz [V] 3 max 1~100-240 Power consumption [W] 3.78 4.71 6.85 10.55 Current consumption [A] 0.048 0.056 0.075 0.106 Air flow in ventilation mode [CFM] 9 18 29 50 Air flow in regeneration mode [CFM] 4 9 15 25 1050 1600 2270 2930 Sound pressure level @ 3 ft [Sones] 0.7 1.5 3.0 4.3 Sound pressure level @ 10 ft [Sones] 0.5 0.7 1.5 2.
Accessories Accessory image Accessory name Stainless steel outer hood for thin walls EH-20 160 400 Murray Road, Cincinnati OH 45217 SF TwinFresh R50 G3 MERV5 filter set (2 pcs.