Instructions / Assembly
Step 7
When the unit is properly located, apply a generous
amount of roofing compound between the flange
and the shingles (do not hot mop) approximately
1-in inside the perimeter of the flange and begin to
secure with nails.
Suggested nailing pattern:
Step 8
Check the installation for leakage with water from a
garden hose. Do not spay water directly into the
vent opening.
THERMOSTAT INSTALLATION
WARNING
Before wiring the thermostat, turn the power off at the breaker to avoid electrocution.
Be certain to confirm to all Local Electric Codes and Regulations.
Remove the cover from the thermostat box and use screws to attach the mounting plate to a stud.
When installing the thermostat box, use screws to attach it to the stud to prevent damage to the control.
Leave the back side of the control unobstructed to allow free air circulation behind the box.
Wire the unit to the incoming power supply according to the diagram below.
The thermostat is adjustable. Recommended setting is 90-110 degrees F depending on local
temperatures.
The fan will run as long as the attic temperature remains above the set temperature.