Installation Instructions

Page 4L116 1210A















12"
9"
12" Transition
Opening 11 ¼"
Above To p
of Hood
1 ¾"
8” Blower
Outlets
Vent Holes
5 ½"
10 ½"
Centerline
of Hood
Centerline
of Hood
Electrical (2)
12" Round
12" Round
11 ¼"
8" Round 8" Round 8" Round
12"
11 1/4"
Installation Details Continued
6) Remove the three screws retaining the blower motor(s). Unplug
and remove the motor(s), taking care not to damage the blower
wheel(s). It is not necessary to remove the blower wheel from
the motor.
8) Extend wires to the liner and insert them into the electrical wire clamp on each motor box. Tighten the wire clamp(s).
From inside the liner, using UL listed wire nuts, attach the “neutral” wire(s) to the white lead(s), the “hot” wire(s) to
the black lead(s), and the ground wire(s) to the green lead(s) inside the motor box(es).
7) Install an appropriate 1/2” UL listed electrical wire clamp through each motor box electrical opening on the top of the
liner. Install electrical wiring from the service panel to the liner location for each motor box. Consult the connection
diagrams (above) for further details on electrical placement.
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
Warning: Do not operate hood without proper ground connection.
1100 CFM T400 Cluster Blower
(Top View)
VP564 Transition
(Included)
Transition Installed
(Side View)
TPSLE Connection Diagram (48”- 66” Widths)
550 CFM T200 Dual Blower
(Top View)
VP565 Transition
(Included)
Transition Installed
(Side View)
TSLE Connection Diagram (36”- 48” Widths)
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T200 Island Dual 115 2.9 60 1550 550 900 507 471 431 8" (50 in.
2
) 6.0
T400 Island Cluster 115 5.8 60 1550 1100 1800 998 855 774 12" (13 in.
2
) 6.4
* Add 0.5 amp for each halogen light.
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
#
RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.