Installation Guide

Page 4L113 0808A
Centerline
Of Hood
5" x 16"
Exhaust
Opening
8" Transition
Opening
Centerline
Of Hood
Vent Holes
Electrical
7 ¾"
12" Transition
Opening 2 ¼”
Above Top of
Hood
8” Blower
Outlets
Centerline
of Hood
Centerline
of Hood
Vent Holes
Electrical (2)
7 ¾”
10 ½”
2 ¼”
18”
18"
12" Round
12" Round
11 ¼"
8" Round 8" Round 8" Round
Brass Screws
A
Blower Wheel
B
Blower Housing
Installation Details Continued
6) Remove the blower shields (A) by loosening the two brass screws on the bottom of the shield. Gently close the back
draft dampers from the top side of the hood. To remove the blower housings, unsnap the suitcase latches (B) (one
on each side of the housing). The housings should be pulled forward and gently “tipped” to clear the blower wheels
and then out of the hood.
Warning: Make sure power is off and locked at the service disconnecting
means on the service panel during installation.
Connection Diagram (48”- 66” Widths)
Connection Diagram (36”- 48” Widths)
550 CFM T200 Dual Blower
(Top View)
1100 CFM T400 Dual Blowers
(Top View)
7) Remove the blower deck assembly by removing the 12 screws around the blower mounting plate. Unplug the electrical
connector(s) and set the blower assembly aside, taking care not to damage the blower wheels.
8) Install an appropriate 1/2” UL listed electrical wire clamp through the electrical strap(s) on top of the hood deck. Install
electrical wiring from the service panel to the hood location for each blower assembly. Consult the connection diagrams
(above) for further details on electrical placement. Support the hood beneath the location where it will hang and feed
the electrical wire(s) into the wire clamp(s). Tighten the wire clamp(s).
Transition Installed
(Side View)
VP565 Standard Transition
(Included)
VP564 Standard Transition
(Included)
Transition Installed
(Side View)
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T200 Island Dual 115 2.9 60 1550 550 900 507 471 431 8" (50 in.
2
) 6.0
T400 Island Cluster 115 5.8 60 1550 1100 1800 998 855 774 12" (13 in.
2
) 6.4
* Add 0.5 amp for each halogen light.
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
#
RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.