Product Specifications
EPIT18/EPITH18/SEPIT18/SEPITH18 “H” in part number indicates halogen lighting. These models
not available with heat lamps. Shown with optional duct cover (sold separately). Optional duct covers
available in standard and custom sizes.
OPTIONAL
DUCT
COVER
OPTIONAL
DUCT
COVER
EUROSTYLE ISLAND RANGE HOOD SPECIFICATIONS
1100 CFM T400 Cluster Blower
(Top View)
12" Transition
Opening 2 ¼”
Above Top of
Hood
8” Blower
Outlets
Centerline
of Hood
Centerline
of Hood
Vent Holes
Electrical (2)
7 ¾”
10 ½”
*Exceeding recommended
mounting height may
compromise performance.
VP564 Standard Transition
(Included)
Transition Installed
(Side View)
12" Round
12" Round
11 ¼"
8" Round 8" Round 8" Round
2 ¼”
18”
U
L
CUS
R
EPIT18/EPITH18 SEPIT18/SEPITH18
Connection Diagram (48" - 66" Widths) Recommended
Mounting Height*
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
•
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T400 Island Cluster 115 5.8 60 1550 1100 1800 998 855 774 12" (13 in.
2
) 6.4
* Add0.5ampforeachhalogenlight.Hoodisavailablewithuorescentlights(twoinfront,twoinback)orwithhalogenlights(4lights:48"-59",8lights:60"-66",+2lightsforeach14"ifover66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1210A