Specification Sheet

BH340PSLB/B446PSLB/BH446PSLB LINER H” in model number designates halogen lighting.
BH340PSLB is available with halogen lights only. This model not available with heat lamps.
Recommended
Mounting Height*
WALL MOUNT LINER INSERT SPECIFICATIONS
1200 CFM Double B200 Dual Blowers
(Top View)
*Exceeding recommended
mounting height may
compromise performance.
11” 11”
5 ½” 5 ½”
Wall Side
5 ¼”
1 ¾”
Electrical (2)
8” Outlet
Vent
Holes
8” Outlet
Centerline
of Hood
Transition centers outlet
over top of hood
12” Round 12” Round
16 ½”
8” Round 8” Round
8” Round
3”
VP563 Transition (Optional) For B400
(Double B200 Dual Blowers)
Connection Diagram (40-3/8" Width)














10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
900 CFM B200 Dual & B100 Single Blowers
(Top View)
VP562 Transition (Optional) For B300
(B200 Dual & B100 Single Blowers)
Connection Diagram (46-3/8" Width)
BH340PSLB/B446PSLB/BH446PSLB
10 OR 12”
Round
U
L
CUS
R
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
* Add0.5ampforeachhalogenlight.TheB446PSLBisavailablewithtwouorescentlights.Bothmodelsareavailablewiththreehalogenlights.
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0210A





