User Guide

35
Advanced Setup Table
cont. next page
Default = Factory Default Setting
Step# Description Pg# Range Default
1 Prog Mode 26 Non, 1, 5/1/1, 7 Day 7
2 Available Modes 26 Heat/Cool/Auto/Off, Heat/Cool/
Heat/Cool/Off, Heat/Off, Auto/Off
Cool/Off
3 Backlight 17 On, Off, 6pm-6am Off
4 Backlight Level 17 Off thru 7 levels of brightness Level 5
5 Night Dimmer 17 On/Off Off
6 Night Dimmer Brightness 17 Off thru 7 levels of brightness 2 (20%)
7 Night Dimmer Start Time 17 12A-12A 8:00P
8 Night Dimmer Stop Time 17 12A-12A 6:00A
9 Current Service Filter Runtime Hours 24 0-1999 Hours 0
10 Current Service Filter Calendar Days 24 0-720 Days 0
11 Current Override Hours 25 0-1999 Hours 0
12 Current UV Lamp Calendar Days 25 0-720 Days 0
13 Set Service Filter Runtime Hours 24 0-1950 hours 0
14 Set Service Filter Calendar Days 24 0-720 Days 0
15 Set UV Lamp Calendar Days 25 0-720 Days 0
16 Language 17 English, Espanol, Francais English
17 Scrolling Method 18 “L-R Slow, L-R Fast, Word Whole Word
L-R Slow, Word L-R Fast, Ctr, Fast
Whole Word L Slow,
Whole Word R Slow,
Whole Word Ctr. Fast,
Whole Word Ctr. Slow”
18 Setpoint Limits 28 0, 1, 2, 3 0
19 Max Heat Setpoint 28 35 - 99 Degrees 74
20 Min Cool Setpoint 28 35 - 99 Degrees 70
21 Cycles Per Hour 28 No Limit, 2, 3, 4, 5, 6 6
22 Compressor Minimum Off Minutes 28 0, 3, 5 Minutes 5
23 Min. Heat/Cool Setpoint Difference 28 0 - 6 Degrees 2
24 Number of Heat Stages 28 0 - 3 2
25 Number of Cool Stages 28 0 - 2 1
26 Number Of Compressor Stages 28 1, 2 1
27 Number of Aux Stages 28 0, 1, 2 0
28 1st Stage Deadband 29 1 - 6 Degrees 2
29 2nd Stage Deadband 29 0 - 10 Degrees 2
30 3rd Stage Deadband 29 0 - 10 Degrees 2
31 4th Stage Deadband 29 0 - 10 Degrees 2
32 Minutes Between 1st and 2nd Stage 29 0 - 60 Minutes 2
33 Minutes Between 2nd and 3rd Stage 29 0 - 60 Minutes 2