User Guide
36
Advanced Setup Table
cont. next page
Df = Factory Default Setting
Step# Description Pg# Range Df
1 Prog Mode 25 Non, 1, 5/2, 7 Day 7
2 Available Modes 25 Heat/Cool/Auto/Off Heat/Cool/
Heat/Cool/Off,Heat/Off, Auto/Off
Cool/Off
3 Backlight 16 On, Off Off
4 Backlight Level 16 Off thru 7 levels of brightness Level 5
5 Night Dimmer 16 On/Off Off
6 Night Dimmer Brightness 16 Off thru 7 levels of brightness 2 (20%)
7 Night Dimmer Start Time 16 12A-12A 8:00P
8 Night Dimmer Stop Time 16 12A-12A 6:00A
9 Current Service Filter Runtime Hours 23 0-1999 Hours 0
10 Current Service Filter Calendar Days 23 0-720 Days 0
11 Current UV Lamp Calendar Days 23 0-720 Days 0
12 Set Service Filter Runtime Hours 23 0-1950 hours 0
13 Set Service Filter Calendar Days 23 0-720 Days 0
14 Set UV Lamp Calendar Days 24 0-720 Days 0
15 Language 16 English, Espanol, Francais English
16 Scrolling Method 17 “L-R Slow, L-R Fast, Word Whole Word
L-R Slow, Word L-R Fast, Ctr, Fast
Whole Word L Slow,
Whole Word R Slow,
Whole Word Ctr. Fast,
Whole Word Ctr. Slow”
17 Setpoint Limits 28 No, Use No
18 Max Heat Setpoint 28 35 - 99 Degrees 74
19 Min Cool Setpoint 28 35 - 99 Degrees 70
20 Cycles Per Hour 28 No Limit, 2, 3, 4, 5, 6 6
21 Compressor Minimum Off Minutes 28 0, 3, 5 Minutes 5
22 Min. Heat/Cool Setpoint Difference 28 0 - 6 Degrees 2
23 Number of Heat Stages 28 0 - 3 2
24 Number of Cool Stages 28 0 - 2 1
25 Number Of Compressor Stages 28 1, 2 1
26 Number of Aux Stages 28 0, 1, 2 0
27 1st Stage Deadband 29 1 - 6 Degrees 2
28 2nd Stage Deadband 29 0 - 10 Degrees 2
29 3rd Stage Deadband 29 0 - 10 Degrees 2
30 4th Stage Deadband 29 0 - 10 Degrees 2
31 Minutes Between 1st and 2nd Stage 29 0 - 60 Minutes 2
32 Minutes Between 2nd and 3rd Stage 29 0 - 60 Minutes 2
1.) Page 27. Simple change to how the
weekend option for program mode is
described. However, this will need to be
changed in the T3700/T3900 as well (spin
doc version #).
2.) Page 28. Simple change to
description of security (options are no
/ use). However, this will need to be
changed in the T3700/T3900 as well (spin
doc version #).
3.) Page 36. I didn’t make the change
in the attached manual cuz I noticed
it when doing the T4900SCH. For the
default scrolling type, dummy ME listed
‘English’ as the default setting. Should
be ‘whole words ctr fast’. So very sorry.
This will need to be changed in all
manuals (spin doc version #).
Thanks Nora,
Terry