Appendix B: Dimensional Drawings
13.375”
[340]
12.005”
[305]
C
D
B
A
TOP VIEW
LeftRight
Back
Front
4.000” [102]
8.000”
[203]
8.000”
[203]
3.535” [90]
4.000”
[102]
28.005”
[711]
14.000”
[356]
5.859” [149]
4.028”
[102]
10.005”
[254]
EA-E
SA-E
Power line
input
Low voltage
terminal strips
Control box
Reversed
door option
LEFT VIEW
A
34.000”
[864]
19.207”
[488]
5.125”
[130]
EA
OA
RA
SA
Note:
For units with the reversed door option, interior
components will appear as a mirror image of the above diagram.
FRONT VIEW
23.500”
[597]
2.750”
[70]
2.750”
[70]
14.000”
[356]
6.500”
[165]
1.800”
[46]
8.000”
[203]
8.000”
[203]
14.103”
[358]
7.705”
[196]
4.000”
[102]
24.500”
[622]
Strap mounting
location
OA-E
RA-E
RIGHT VIEW
B
Condensate drain
12.000”
[305]
Control box
cover plat
e
FRONT VIEW
15.000”
[381]
Access door
Heat recovery core
Reversed
door option
RIGHT VIEW
Poly Core Aluminum Core HM Core
PTS LBS Kg PTS LBS Kg PTS LBS Kg
A 38 17 A 40 18 A 41 19
B 25 11 B 26 12 B 27 12
C 52 24 C 55 25 C 56 25
D 33 15 D 34 15 D 35 16
TOTAL 148 67 TOTAL 155 70 TOTAL 159 72
Connection Table
Connection Sizes
A Line voltage in 14 gauge wire nut
B Condensate drain fitting (2x) 3/4” MPT
Notes:
Dimensions in [ ] are millimeters.
Center of gravity
Direction of airflow
A minimum of 15.000” [381] clearance from any obstruction is required for removal of heat recovery cores, fans, etc.
This model has a damper located on the outdoor intake connection. This damper will close during a frost control cycle
or when the unit is placed in the ‘Off‘ position with power maintained to the unit. This damper is not designed as a
backdraft damper and will remain open if power is disconnected from the unit for any reason.
Note: The access door can be removed from the
cabinet with only 2.000” [51] of clearance.
Note:
A minimum of 12.000” [305] clearance from any
obstruction is required for removal of the control box.
Figure B1: HRV600i unit dimensional drawing (with exhaust only defrost)
VCES-HRV-IOM-1C – HRV600i, HRV700i, HRV1200i
18