User manual
Chapter 3 Entering softpatch 3 - 13
Setting default full level
The default full setting is the level
MicroVision FX
enters for selected
channels when you press [Full]. The default setting for full is 100 per-
cent, and is reset to 100 percent after a diagnostic system clear.
When you set the default full level below 100 percent, you can still set
channels above the [Full] setting by using [At], [+], [-], or the fader wheel.
To set [Full] at a level other than 100 percent, follow these steps:
1. Press [Set Up].
2. Select 7, System settings, and press [Enter].
3. Select 3, Default full level, and press [Enter].
4. Either enter a two-digit intensity level, or press [Full] to set levels at
100 percent.
Note: When you set dimmer levels on the softpatch screen, [Full]
enters 100 percent regardless of the default full level setting.