User manual

Chapter 2 Installation 2 - 7
Digital outputs (DMX512 and D192)
Connector
XLR 5-pin female
512 digital multiplex dimmers
Pinout
1 Common
2 Data (-) (DMX512 and D192)
3 Data (+) (DMX512 and D192)
4 Not used
5 Not used
AMX192, CD80 analog multiplex output (optional)
Connector
XLR 4-pin male
(Either one connector for 192 outputs, or two connectors for 384
outputs; 192 outputs per connector)
Pinout
1 Common (Earth ground)
2 Clock (+)
3 Analog data
4 Clock (-)
Note: You can configure MicroVision FX for Strand CD80 Dimmer I and
Dimmer II cabling convention (maximum 192 ouitputs). Contact an
authorized dealer or ETC if you need more information on connecting to
CD80 racks.
Analog wire-per-dimmer output (optional)
Connector
Centronics D-36 female
Pinout
Connector one Pins 1-32 = dimmers 1-32
Connector two Pins 1-32 = dimmers 33-64
Connector three Pins 1-32 = dimmers 65-96
All connectors Pins 33-36 = common (Earth ground)