Instruction manual

!
!
2.1 Installation
Pumps and lters should be connected in the prescribed way.
The user always has to consider personal safety and health for himself as well as his direct vicinity.
2.2 Electrical
1. Only qualied electricians are allowed to connect pumps according to local regulations of the power supplier.
2. Grounding of the motor should be applied rst; failure to ground can cause severe or fatal shock. Do not ground to gas
supply lines.
3. Before connecting the motor check corresponding voltage of motor and power supply. Incorrect connection can cause re
or serious damage to the motor and voids warranty. See wiring diagram.
4. Avoid unexpected or accidental starting of the motor by disconnecting and locking out power supply.
5. In case of repair and maintenance disconnect and lock out power supply.
6. Do not point a jet of water at the motor to avoid personal injury (risk of electrical shock).
7. Check wiring dimensions according to the power of the motor.
8. Check fuses on the power supply connection.
9. Thermal overload switch should be used on the connection to the pump. The current overload is adjusted to the value of the
motor name plate including +10%.
10. Do avoid damage to the cord line by not hoisting the pump by the cord line and be sure the cord line is not jammed;
avoid sharp edges.
11. General rule for Hendor pump shaft rotation: Always run clockwise (CW), looking at cooling fan side.
Direction of rotation is also indicated on the motor by arrow.
2.3 Checking direction of rotation
Vertical pumps: Always check direction of rotation outside the liquid.
Horizontal pumps: Always check the direction of rotation ooded with liquid.
Briey switching on the power will show direction of rotation, looking at cooling fan side. Ignoring these recommendations will
damage the pump severely.
2.4 Plumbing
1. Connections to the pump and lter should be provided with reliable, persistent materials.
2. Where hoses are used, take care of correct hose clamps.
3. Use the right O-rings for connections.
4. Pipes and hoses should be internally cleared of any obstructions.
5. Check tightness of connections before starting up.
6. Thermoplastic components will not tolerate any plumbing stress.
7. Plumbing should be properly aligned and supported to prevent distortion and damage of parts.
8. Leave enough space for easy access and/or maintenance.
9. Keep position of pump away from any heaters or heater coils.
10. Pumps and lters should be mounted on a sturdy base.
3. Receipt
At receipt of the product the identity of the product (by checking name plate data), the completeness of delivery as well as absence
of visible damage should be ascertained. The end-user or his representative must ascertain the match of material specication and
specic liquid used. Any problems arising from these checks should be made in writing and preferably signed by the forwarding agent as
evidence.
U1 V1 W1
W2 U2 V2
U1 V1 W1
L1 L2 L3
W2 U2 V2
L1 L2 L3
r
I
N L
single phase
3-phase
© Hendor - Quality Pumps & Filters - 2 - Info 28640/R0