Technical information

Ultrasonic Level Sensor LUC-M**
Ordering information
DOCT-0805F 01/2010 185414
24
Product structure
LUC-M30
Product structure
LUC-M40
LUCM30–
Certificate
NA version for non-explosion hazardous areas
ES ¬ II 1/2 D, aluminium cover
E2 ¬ II 1/3 D
FM FM DIP, Cl. II, Div.1 Group E-G, N.I .Cl. I, Div.2
CG CSA, General Purpose
CS CSA DIP, Cl. II, Div. 1, Group E-G, N.I .Cl. I, Div.2
Display
A * prepared for remote display, order display as accessory LUC-Z40
B without display
D with display LUC-Z15 inclusive on-site operation, envelope curve display
Electrical output
AH 4-wire, 90 V AC ... 250 V AC, 4 mA ... 20 mA, HART
DH 4-wire, 10.5 V DC ... 32 V DC, 4 mA ... 20 mA, HART
PA 2-wire, PROFIBUS PA
Cable entry
2 cable gland M20 x 1,5
3 thread G½
4 thread ½ NPT
5 connector M12, PROFIBUS PA
Housing
A1 aluminium housing F12, IP68, thread M20 x 1.5
Prozess connection
FA universal flange DN100/ANSI 4"/JIS16K100, PP
FS universal flange DN100/ANSI 4"/JIS16K100, 316Ti
FK without slip-on flange, without mounting bracket, customer mounting equipment
FM with mounting bracket LUC-Z17 * in preparation
LUCM40–
Certificate
NA version for non-explosion hazardous areas
EX ¬ II 1/2 G EEx ia IIC T6
SX ¬ II 1/2 G EEx d (ia) IIC T6
S2 ¬ II 3G EEx nA II T6
F1 FM IS, Cl. I/II/III, Div.1 Group A-G, N.I .Cl. I, Div.2
F2 FM XP, Cl. I/II/III, Div. 1, Group A-G
CG CSA, General Purpose
C1 CSA IS, Cl. I/II/III, Div. 1, Group A-D, G + coal dust, N.I.
C2 CSA XP, Cl. I/II/III, Div. 1, Group A-D, G + coal dust, N.I.
Additional option
A basic version
Sealing sensor/flange
2 Viton
3 EPDM
Display
A * prepared for remote display, order display as accessory LUC-Z40
B without display
D with display LUC-Z15 inclusive on-site operation, envelope curve display
Electrical output
AH 4-wire, 90 V AC ... 250 V AC, 4 mA ... 20 mA, HART
DH 4-wire, 10.5 V DC ... 32 V DC, 4 mA ... 20 mA, HART
PA 2-wire, PROFIBUS PA
IH 2-wire, 4 mA ... 20 mA, HART
Cable entry
2 cable gland M20 x 1.5
3 thread G½
4 thread ½ NPT
5 connector M12, PROFIBUS PA
Housing
A1 aluminium housing F12, IP68, thread M20 x 1.5
A2 aluminium housing T12, IP68, coated, with separate terminal compartment
A4 aluminium housing T12, IP68, coated, with separate terminal compartment, overvoltage protection
Process connection; max. 3 bar abs/44 psia, hole circle PN16/150 lbs/10K
P universal flange DN80/ANSI 3"/JIS10K80, PP
Q universal flange DN80/ANSI 3"/JIS10K80, PVDF
S universal flange DN80/ANSI 3"/JIS10K80, 316L
T universal flange DN100/ANSI 4"/JIS16K100, PP
U universal flange DN100/ANSI 4"/JIS16K100, PVDF
V universal flange DN100/ANSI 4"/JIS16K100, 316L
M mounting bracket LUC-Z17 * in preparation