User guide

Services Configuration
Rev 2.3 Feb.12 97
Time Delay + Low
Voltage
If you select this option, the device will delay going into Low Power mode caused by a low
voltage drop (below threshold) or ignition off.
Low Voltage Threshold: Set the voltage level at which the device goes into low power
mode (threshold in tenths of volts).
Example: VLTG=130 would place the device in a low power standby state if the voltage
goes below 13.0V.
Low Power Mode Delay (Minutes): The number of minutes after one of the Low Power
events happens until the AirLink device enters the Low Power mode.
Note: There is always a minimum of 1 minute between the power down event and actual
shutdown (to give the AirLink device time to prepare); entering zero, for Low Power Mode
Delay, will not power down the device immediately.
Periodic Timer If you select the Periodic Timer, two fields display:
Periodic Timer Active Duration - Enter the time for how long the device needs to be in
Active mode
Period Timer Inactive Duration - Enter the time for how long the device should be
inactive after the Active mode expires.
The Low Power mode process will repeat in a cyclical way (active and inactive).
Field Description