Specifications

MP 700 Series GPS AT Command Reference
40 2130309
!MPDIOCFG=
<chan>,<type>,
"<IO label>", <alarm>,
"<logic low label>",
"<logic high label>",
[<level>]
!MPDIOCFG?
<chan>
Digital I/O channel configuration
Sets the type (input or output), labels, and alarm trigger, for the specified I/O
channel.
Parameter settings
The supported values are:
Channel <chan>=
1 Digital I/O 1—Pin 3 (input or output)
2 Digital I/O 2—Pin 4 (input only)
3 Digital I/O 3—Pin 11 (input or output)
4 Digital I/O 4—Pin 12 (input only)
Input/output type <type>=
0 Input
1 Output (only valid for channel 1 and 3)
Sensor or gauge description <IO label>=
20 character string
Alarm trigger <alarm>=
0 No alarm; no logging
1 Alarm triggered (and event logged) when logic level low occurs
2 Alarm triggered (and event logged) when logic level high occurs
3 No alarm; any change in logic level is logged
The name and location of the log file is set in Watcher. (See the Watcher online help
for details.)
State when logic level is low <logic low label>=
20 character string
State when logic level is high <logic high label>=
20 character string
Output level <level>=
This parameter is only valid for channels 1 and 3 and only where <type>=1.
0 Low
1 High
!MPDIOCFG? returns the configuration values for the specified channel.
!MPFBKEND=
<value>
!MPFBKEND?
Set response to GPRS re-acquisition
Determines how the modem behaves if GPRS service is re-acquired during a
Fallback connection (See !MPFBSETUP.)
The <value> setting determines whether the dial-up connection is maintained:
<value>=0 Disconnect immediately
<value>=1 Maintain dial-up connection (Default)
(Disconnecting may save excess charges for dial-up services.)
!MPFBKEND? returns the current setting.
Table 3-9: Command Reference Table (ASCII Alphabetic)
Command Description