6.6.5.1 Overview of control words and setpoints
Table 6- 11 Overview of control words and setpoints
Abbreviation Description Parameter Function diagram
STW1 Control word 1 (interface mode SINAMICS,
p2038 = 0)
See table "Control word 1 (interface
mode SINAMICS, p2038 = 0)"
FP2442
STW1 Control word 1 (interface mode VIK-NAMUR,
p2038 = 2)
See table "Control word 1 (interface
mode VIK-NAMUR, p2038 = 2)"
FP2441
STW1_BM Control word 1, metal industry (interface mode
SINAMICS, p2038 = 0)
See table "Control word 1, metal
industry (interface mode SINAMICS,
p2038 = 0)"
FP2425
STW2 Control word 2 (interface mode SINAMICS,
p2038 = 0)
See table "Control word 2 (interface
mode SINAMICS, p2038 = 0)"
FP2444
STW2_BM Control word 2, metal industry (interface mode
SINAMICS, p2038 = 0)
See table "Control word 2, metal
industry (interface mode SINAMICS,
p2038 = 0)"
FP2426
E_STW1 Control word 1 for infeeds See table: "Control word 1 for
infeeds"
FP2447
E_STW1_BM Control word 1 for infeeds, metal industry See table: "Control word 1 for
infeeds, metal industry"
FP2427
NSOLL_A Speed setpoint A (16-bit) p1070 FP3030
NSOLL_B Speed setpoint B (32-bit) p1155 FP3080
PCS7_x PCS7-specific setpoints