Operating instructions

Operation
6.6 PROFIBUS
Drive converter cabinet units
218 Operating Instructions, 10/2008, A5E00288214A
Note
If p0922 = 999, a telegram can be selected in p2079. A telegram interconnection is
automatically made and blocked. However, the telegram can also be extended.
This is an easy method of creating extended telegram interconnections on the basis of
existing telegrams.
6.6.5 Structure of the telegrams
Table 6- 10 Structure of the telegrams
Telegr. PZD 1 PZD 2 PZD 3 PZD 4 PZD 5 PZD 6 PZD 7 PZD 8 PZD 9 PZD 10
STW1 NSOLL_A 1
ZSW1 NIST_A
STW1 NSOLL_B STW2 2
ZSW1 NIST_B ZSW2
STW1 NSOLL_B STW2 G1_STW 3
ZSW1 NIST_B ZSW2 G1_ZSW G1_XIST1 G1_XACT2
STW1 NSOLL_B STW2 G1_STW G2_STW 4
ZSW1 NIST_B ZSW2 G1_ZSW Further assignment, see FP2420
STW1 NSOLL_A 20
ZSW1 NIST_A_
GLATT
IAIST_
GLATT
MIST_
GLATT
PIST_
GLATT
MELD_
NAMUR
STW1_
BM
NSOLL_B STW2_BM M_ADD M_LIM free free free free 220
ZSW1_
BM
NIST_A IAIST MIST WARN_
CODE
FAULT_
CODE
ZSW2_
BM
free free free
STW1 NSOLL_A PCS7_3 PCS7_4 PCS7_5 PCS7_6 352
ZSW1 NIST_A_
GLATT
IAIST_
GLATT
MIST_
GLATT
WARN_
CODE
FAULT_
CODE
E_STW
1
370
E_ZSW
1
E_STW
1_BM
free free free free 371
E_ZSW
1_BM
IAIST WARN_
CODE
FAULT_
CODE
free free free free
STW1 free free free free free free free free free 999
ZSW1 free free free free free free free free free