Operating instructions

Operation
6.4 Command sources
Drive converter cabinet units
Operating Instructions, 10/2008, A5E00288214A
203
6.4.4 "PROFIdrive NAMUR" default setting
Prerequisites
The NAMUR terminal block (option B00) is installed in the cabinet unit.
The "PROFIdrive" default setting was chosen during commissioning:
STARTER:
"PROFIdrive Namur"
AOP30:
"10: PROFIdrive Namur"
Command sources
U0DVWHUFRQWURODFWLYH
5(027(352),GULYH1$085
/2&$/2SHUDWRUSDQHO67$57(5
%XWWRQ/2&$/5(027($23
$VVXPHPDVWHUFRQWURO67$57(5
,QWHUQDOFRQWURO
2SHUDWRUSDQHO$23
&RQWUROSDQHO67$57(5
352),%86352),1(7
1$085WHUPLQDOV;
Figure 6-15 Command sources - AOP30 ←→ PROFIdrive NAMUR
Priority
The priority of the command sources is shown in the diagram "Command sources -
AOP30←→PROFIdrive NAMUR".
Note
The EMERGENCY STOP and motor protection signals are always active (regardless of the
command source).
All of the supplementary setpoints are deactivated for LOCAL master control.