Parameter
p0120
Power Module data sets (PDS) number
p0130
Motor data sets (MDS) number
p0139[0...2]
Copy motor data set (MDS)
p0140
Encoder data sets (EDS) number
p0170
Command data set (CDS) number
p0180
Drive data set (DDS) number
p0186
Assigned motor data set (MDS)
p0187[0...n]
Encoder 1 encoder data set number
p0188[0...n]
Encoder 2 encoder data set number
p0189[0...n]
Encoder 3 encoder data set number
p0809
Copy command data set CDS
p0810
BI: Command data set selection CDS bit 0
p0811
BI: Command data set selection CDS bit 1
p0819[0...2]
Copy drive data set DDS
p0820
BI: Drive data set selection, bit 0
p0821
BI: Drive data set selection, bit 1
p0822
BI: Drive data set selection, bit 2
p0823
BI: Drive data set selection, bit 3
p0824
BI: Drive data set selection, bit 4
6.3.4 BICO technology: Interconnecting signals
Description
Every drive contains a large number of interconnectable input and output variables and
internal control variables.
BICO technology ( Binector Connector Technology) allows the drive to be adapted to a wide
variety of conditions.
Digital signals, which can be connected freely by means of BICO parameters, are identified
by the prefix BI, BO, CI or CO in their parameter name. These parameters are identified
accordingly in the parameter list or in the function diagrams.
Note
The STARTER parameterization and commissioning tool is recommended when using BICO
technology.