Applications
*DIGITALIN[n]? Query individual digital inputs. The digital inputs report either a 0 (open) or 1 (closed).
AT*DIGITALIN[n]?
n=1–5 (Input number)
Note: Digital inputs 2, 3, 4, and 5 are only available on an AirLink GX Series device with an
I/O X-Card installed. To confirm that an I/O X-Card is installed, check the X-Card Type field
on Status > Home.
*PULSECNT[n]? Query the I/O pulse counts for digital in.
AT*PULSECNT[n]?
•n=15
Note: Pulse counts 25 are only available on a GX Series device with an I/O card installed.
*RELAYOUT[#] Query or set the relay status.
AT*RELAYOUT[#]? to query
AT*RELAYOUT[#]=n to set
•# = 15
•n=0OFF
n=1Drive Active Low
Note: Relay outputs 3, 4, and 5 are only available on an AirLink GX Series device with an
I/O X-Card installed. To confirm that an I/O X-Card is installed, check the X-Card Type field
on Status > Home.
Table D-12: Input/Output AT Commands (Continued)
Command Description
Volts Digital value
-0.5 1.2 0
1.3 30 1
Table D-13: Applications > Data Usage Commands
Command Description
*DATACURDAY? Display data usage for the current day (in KB).
*DATAPLANUNITS Query or set the units for the data usage report
AT*DATAPLANUNITS to query
AT*DATAPLANUNITS=n to set
n=1Sets the units to Megabytes (MB)
n=2Sets the units to Kilobytes (KB)