User guide

Rev 1 Oct.13 371
I/O
V Query or set the AT command responses (verbosity).
ATV? to query
ATVn to set
n=0 — Numeric (terse) command responses (The numeric responses follow the Hayes
Standards for commands.)
n=1 — Text string (verbose) command responses (default)
Note: Do not use an equal sign (=) when issuing the command.
&V Lists most AT commands and their current values. If the parameter is not configured, the AT
command returns “Not Set”.
&W Saves the settings for parameters that are temporarily set without being permanently written
to the memory.
This command does not apply to ALEOS because once you issue an AT command or
change a setting in ACEmanager and click Apply, the changes are saved in non-volatile
memory and are persist across reboots.
X Query or set the Extended Call Process Result mode
ATX? to query
ATXn to set
n=0 — No extended code (default)
n=1 — Adds the text 19200 to the connect response
Z Reboots the AirLink device.
Note: If *DATZ is set to 1, Z is blocked. See *DATZ on page 368.
Table D-11: Standard (Hayes) AT Commands (Continued)
Command Description
Table D-12: Input/Output AT Commands
Command Description
*ANALOGIN[n]? Query individual analog input values (in volts).
AT*ANALOGIN[n]?
•n=14
Note: Four analog inputs are available on an AirLink GX Series device with an I/O X-Card
installed. To confirm that an I/O X-Card is installed, check the X-Card Type field on Status >
Home.
One analog input is available on the AirLink LS300.