S50 Query or set the data forwarding idle time-out.
ATS50? to query
ATS50=n to set
n=0— a forwarding time-out of 10ms is used.
n= tenths of a second
S51 Query or set the PAD data forwarding character. ASCII code of character that causes data
to be forwarded. Used in UDP or TCP PAD mode.
ATS51? to query
AT51=CHARACTER to set
n=0 — No forwarding character
n= CHARACTER
S53 Query or set the method (dial mode), destination IP address, and port used as defaults for
the D (Dial) AT command.
ATS53? to query
ATS53=[method][d.d.d.d][/ppppp] to set
[method] can be:
P — UDP
T — TCP
[d.d.d.d] is the destination IP address
[pppp] is the port number.
Example:
ATS53=P111.22.33.44/5555
where:
The first character is the dial mode (P in this example)
Followed by destination IP address (111.22.33.44 in this example)
A slash
Followed by the destination port (5555 in this example)
You can also use this command to set only the port. For example, AT53=/7777.
S60 Query or set the Telnet Client Echo Mode.
ATS60? to query
ATS60=n to set
n=0 — No Echo
n=1 — Local Echo (Default)
n=2 — Remote Echo
S82 Query or set UDP auto answer.
ATS82? to query
ATS82=n to set
n=0 — Disable
•n=1 Enable