User guide
ALEOS 4.3.4 Software Configuration User Guide
240 4114514
Table 11-8: Serial > X-Serial Port Configuration >Advanced and TCP Configuration
Field Description
TCP Auto Answer This determines how the AirLink device responds to an incoming TCP connection
request. The AirLink device remains in AT Command mode until a connection request is
received. The AirLink device sends a “RING” string to the host. A “CONNECT” sent to
the host indicates acknowledgment of the connection request and the TCP session is
established.
Options are:
• Enable
• Disable (default)
You can also use an AT command to configure this field. See S0 on page 369.
TCP Connect Timeout
(seconds)
Specifies the number of seconds to wait for a TCP connection to be established when
dialing out
You can also use an AT command to configure this field.
TCP Idle Timeout TCP idle time-out in the configured units (See TCP Idle Timeout Unit on page 231.)
Specifies a time interval upon which if there is no in or outbound traffic through a TCP
connection, the connection is terminated.
Default is 0.
You can also use an AT command to configure this field. See TCPT on page 365.
TCP Idle Timeout Unit Units used for the TCP Idle Timeout interval
Options are:
• Minutes (default)
• secs
You can also use an AT command to configure this field. See TCPS on page 365.
TCP Connect Response
Delay (seconds)
The number of seconds to delay the “CONNECT' response upon establishing a TCP
connection, or the number of tenths of seconds to delay before outputting ENQ on the
serial port after the CONNECT when the ENQ feature is enabled.
• n=0–255
You can also use an AT command to configure this field. See S221 on page 370.