User guide
Serial Configuration
Rev 1 Oct.13 239
TCP Settings
Figure 11-9: ACEmanager: Serial > IO X-Card Serial Port > TCP
Convert 12 digit Number
to IP Address
Choose whether or not a 12-digit number is converted to an IP address
For example, converts 111222333444 to 111.222.333.444
Options are:
• Use as Name (default)
• Use as IP
You can also use an AT command to configure this field. See *NUMTOIP on page 363.
Disable ATZ Reset The value set in this field determines whether or not issuing an ATZ Command resets
the AirLink device. Options are:
• On (default) — ATZ does not reset the AirLink device
• Off —ATZ resets the AirLink device.
You can also use an AT command to configure this field. See *DATZ on page 368.
IP List Dial This allows access to the Modbus IP Address using the first two digits of the dial string.
For example, ATDT1234567 would imply ID index 12 on the Modbus Address list and
use the associated IP Address as the destination.
Options are:
• Enable
• Disable (default)
You can also use an AT command to configure this field. See IPL on page 363.
Table 11-7: Serial > X-Serial Port Configuration >Advanced and TCP Configuration
Field Description