User guide
Serial Configuration
Rev 1 Oct.13 235
Figure 11-6: Serial > MODBUS Address List
4. Click Apply.
5. Reboot.
To delete an address from the list, click the X beside it.
Note: You can also use the AT Commands MLIST and MLISTX to add address entries and
MLIST? or MLISTX? to query the entries on the list. See MLIST on page 362, and MLISTX
on page 362.
I/O X-Card Serial Port Configuration
This section applies only to the AirLink GX Series device with an I/O X-Card
installed. The serial port on the I/O X-Card is a standard RS232 port using five
wires: RX, TX, RTS, CTS, and GND. The following are not supported: RI, DCD,
DTR, and DSR. For more information on the I/O X-Card, refer to the AirLink GX
Series User Guide.
To configure the serial port for the installed I/O X-Card:
1. In ACEmanager, go to Serial > I/O X-Card Serial Port.