UDP
Figure 11-4: ACEmanager: Serial > Port Configuration > UDP
Table 11-4: Serial Port Configuration > UDP
Field Description
UDP
UDP Auto Answer Whether the AirLink device auto answers and incoming UDP connection request
Options are:
Disable (default)
Enable
You can also use an AT command to configure this field. See S82 on page 364.
UDP Idle Timeout
(seconds)
UDP Idle Time-out in seconds
Specifies a time interval upon which if there is no in or outbound traffic through a UDP
connection, the connection is terminated.
n=0 No idle time-out (Default)
n=1255 Time-out in seconds
You can also use an AT command to configure this field. See S83 on page 365.
UDP Connect Last Allows you to choose to use the last accepted IP address and port number as the default
settings, instead of using S53 (destination address)
Options are:
Do not change S53 (default)
Set S53 last IP
Note: Resetting the device restores the configured S53 (destination address).
You can also use an AT command to configure this field. See *UDPLAST on page 365.