User guide
Serial Configuration
Rev 1 Oct.13 229
Enable CTS Assert CTS when there is network coverage. Options are:
• Disable (default)
• Enable
You can also use an AT command to configure this field. See *CTSE on page 360.
DTR Mode Use DTR from the serial device, or ignore DTR (same as S211 on page 370). Options are:
• Use DTR
• Ignore DTR (default)
Quiet Mode Disable or enable display of device responses. Options are:
• Disable (default)
• Enable
You can also use an AT command to configure this field. See Q on page 368.
AT Verbose Mode Sets the level of information returned for AT commands
Options are:
• Verbose (default)
• Numeric
You can also use an AT command to configure this field. See V on page 371.
Call Progress Result
Mode
When enabled adds 19200 to CONNECT messages
Options are:
• Disable (default)
• Enable
You can also use an AT command to configure this field. See X on page 371.
Convert 12 digit
Number to IP Address
Choose whether a 12-digit number is converted to an IP address (eg. 111222333444 to
111.222.333.444). Options are:
• Use as Name (default)
• Use as IP
You can also use an AT command to configure this field. See *NUMTOIP on page 363
Disable ATZ Reset The value set in this field determines whether or not issuing an ATZ Command resets the
AirLink device. Options are:
• On — Block is enabled—ATZ does not reset the device.
• Off —Block is disabled—ATZ resets the device. (default)
You can also use an AT command to configure this field. See *DATZ on page 368.
IP List Dial This allows access to the Modbus IP Address using the first two digits of the dial string. For
example, ATDT1234567 would imply ID index 12 on the Modbus Address list and use the
associated IP Address as the destination. Options are:
• Disable (default)
• Enable
You can also use an AT command to configure this field. See IPL on page 363.
Table 11-2: Serial Port Configuration > Advanced
Field Description