Low Power Mode
(continued)
Periodic Timer Daily Mode
This mode allows you to specify when the device should be active and when it should be in
Low Power mode on a daily basis. If you select the Periodic Timer Daily Mode, two
additional fields display:
Periodic Timer Start Time (00:00–23:59 UTC) — Enter the time to start the AirLink
device in the Active mode.
Period Timer Active Duration (00:00–23:59 UTC) — Enter the time for how long the
device should be active.
The device will become active at the start time (UTC) and stay active for the active
duration.
Engine HoursALEOS can start and stop counting engine hours based on:
Voltage on the Power Pin from the vehicle battery (Engine Hours On Voltage Level)
Voltage on the ignition Sense Pin (Engine Hours Ignition Enable)
If you configure both fields, both conditions must be met before the device begins counting engine hours.
Engine Hours On
Voltage Level (.1 Volt)
If you want to use this field to trigger counting engine hours, the AirLink device must be
using the vehicle battery as a power source (i.e. Pin 1 [VCC] and Pin 2 [ground] on the
AirLink device’s power connector are connected to the vehicle battery).
a
Enter the voltage level above which the AirLink device starts counting engine hours. When
the voltage from the vehicle battery falls below that value, the device stops counting engine
hours. Enter the desired value in .1 volt units. For example, to set the voltage level at 13.0
volts, enter 130.
The default value is 0, which means the feature is disabled. Engine hours are not
incremented based on the power pin voltage level.